Performance evaluation of ventilative cooling systems for buildings under different control parameters and strategies

Journal Article (2023)
Author(s)

Yan Hu (Hunan University)

Zhengxuan Liu (Hunan University, TU Delft - Design & Construction Management)

Zhengtao Ai (Hunan University)

Guoqiang Zhang (Hunan University)

Research Group
Design & Construction Management
Copyright
© 2023 Yan Hu, Zhengxuan Liu, Zhengtao Ai, Guoqiang Zhang
DOI related publication
https://doi.org/10.1016/j.jobe.2022.105627
More Info
expand_more
Publication Year
2023
Language
English
Copyright
© 2023 Yan Hu, Zhengxuan Liu, Zhengtao Ai, Guoqiang Zhang
Research Group
Design & Construction Management
Bibliographical Note
Green Open Access added to TU Delft Institutional Repository 'You share, we take care!' - Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.@en
Volume number
65
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Ventilative cooling is an energy-saving technology to diminish thermal discomfort and overheating risk of buildings, meanwhile achieving high indoor air quality (IAQ). However, there is still no optimal control strategy in practice, which considerably limits its application. This study developed a typical office building model to evaluate the performance of ventilative cooling systems with different control parameters and strategies for five typical cities in different climatic zones of China. Results showed that, when the control parameter was selected as the upper limit of satisfied comfortable zone by 90% of the occupants, the adaptive thermal comfort (ATC) model, which outperformed the other models in terms of outdoor air utilization, was not necessarily optimal in terms of energy efficiency. The outdoor air utilization potential based on the indoor dry-bulb air temperature (Td) and indoor operative temperature (Top) control was similar, but the energy usage varies considerably, especially in the hot climatic zones. When the overheating period controlled based on the thermal comfort models was the same, the energy usage would be underestimated by 16%–38% without considering the effect of radiant temperature. The ATC-based control could have up to 37% of energy-saving compared to thermostatic control, but inappropriately low limits could make it less advantages to achieve energy-saving. The energy-saving potential associated with the PMV and ATC controls showed a completely opposite trend in the different climatic zones. The analysis results indicate that eliminating the drawbacks of the lower limit in the ATC model is an effective way to demonstrate energy-saving effectiveness. The findings of this study will contribute to the effective improvement of the application potential of ventilative cooling in different climatic zones.

Files

1_s2.0_S2352710222016333_main.... (pdf)
(pdf | 8.88 Mb)
- Embargo expired in 01-07-2023
License info not available