Searched for: author%3A%22Veljkovic%2C+M.%22
(1 - 3 of 3)
document
Yan, R. (author), Xin, H. (author), Veljkovic, M. (author), Da Silva, Luís Simões (author)
In traditional end plate column splices, bolts are placed double symmetrically on the four sides of square hollow sections (SHS). In order to reduce the required gap between the façade and the column, the end plate could be flushed on one or two sides of SHS for the column along the façade or at the corner of a building, respectively. However...
journal article 2023
document
Tran, Anh Tuan (author), Bernspång, Lars (author), Veljkovic, M. (author), Rebelo, Carlos (author), Da Silva, Luís Simõ ões (author)
This paper describes a study of the behaviour of cold-formed high strength steel angles. Thirty-six specimens with different cold-formed angles (90°, 100°, 120°, 140°, 160°, and 170°) and different thicknesses (4 mm and 6 mm) were considered. The initial geometric imperfections of the specimens were determined using the 3D laser scanning...
journal article 2019
document
Jovašević, S. (author), Correia, J. A F O (author), Pavlovic, M. (author), Rebelo, C. (author), De Jesus, A. M P (author), Veljkovic, M. (author), Da Silva, L. Simões (author)
A steel hybrid structural solution for onshore wind turbine towers was proposed in the European project SHOWTIME. This solution is used in the lattice structure for the lower portion of the tower. Recently, a procedure for fatigue life estimation of steel half-pipes bolted connections applied in global structural models using multiaxial Smith...
journal article 2016