Searched for: subject%3A%22Integration%22
(1 - 5 of 5)
document
Hopf, Y.M. (author), Ossenkoppele, Boudewine W. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The...
journal article 2022
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This article presents a compact analog front-end (AFE) circuit for ultrasound receivers with linear-in-dB continuous gain control for time-gain compensation (TGC). The AFE consists of two variable-gain stages, both of which employ a novel complementary current-steering network (CCSN) as the interpolator to realize continuously variable gain....
journal article 2022
document
Ouyang, B. (author), Li, Yanlu (author), Kruidhof, Marten (author), Horsten, R.C. (author), Baets, Roel (author), van Dongen, K.W.A. (author), Caro-Schuurman, J. (author)
We report a highly sensitive ultrasound sensor based on an integrated photonics silicon Mach-Zehnder interferometer (MZI). One arm of the MZI is located on a thin membrane, acting as the sensing part of the device. Ultrasound waves excite the membrane's vibrational mode, thus inducing modulation of the MZI transmission. The measured sensor...
conference paper 2020
document
Sun, S. (author), Kooij, B.J. (author), Yarovoy, Alexander (author)
In this paper, the generalized multiple measurement vectors (GMMV) linear inversion method is applied to the reconstruction of the 3-D Fresnel data, provided by the Institue Fresnel (Marseille, France). The results show that the GMMV-based method can obtain good resolution along the x- and y- axes, while poor resolution along the z-axis,...
conference paper 2019
document
van Berkel, S.L. (author), Malotaux, E.S. (author), Cavallo, D. (author), Spirito, M. (author), Neto, A. (author), Llombart, Nuria (author)
The design and performance analysis are presented for a passive uncooled radiometer pixel suitable for integration in 28 nm CMOS technology. In the configuration a single wideband antenna, operating from 200 GHz to 600 GHz, is connected to a pn-junction diode. Including the antenna-detector impedance mismatch, the detector shows an average NEP...
conference paper 2017
Searched for: subject%3A%22Integration%22
(1 - 5 of 5)