- document
-
Graas, Adriaan B.M. (author), Wagner, E.C. (author), van Leeuwen, Tristan (author), van Ommen, J.R. (author), Batenburg, K. Joost (author), Lucka, Felix (author), Portela, L. (author)A new X-ray computed tomography technique for the purpose of imaging fluidized beds is presented. It consists of an experimental set-up with three stationary X-ray source and flat panel detector pairs, a geometric calibration and data processing workflow, and an image reconstruction algorithm. The technique enables sparse-angular tomographic...journal article 2024
- document
-
Mandalahalli, M.M. (author), Wagner, E.C. (author), Portela, L. (author), Mudde, R.F. (author)In this work, the effect of an electrolyte (up to 2 M of NaCl dissolved in water) on a homogeneous dense bubbly flow, in an airlift bubble column, is studied using nonintrusive techniques. X-ray and high-speed imaging are used to investigate the bubble size distribution, the local and the global gas-fraction profiles. The major effect of the...journal article 2019