Searched for: subject%3A%22corrosion%22
(1 - 3 of 3)
document
Geiker, M. R. (author), Hendriks, M.A.N. (author), Elsener, B. (author)
In Europe, design for the durability of new reinforced concrete structures is currently based on a prescriptive approach. The design, execution (construction) and planned maintenance of a concrete structure have to lead to the intended level of safety and serviceability throughout its entire service life. This requires numeric models based on...
journal article 2021
document
Angst, Ueli M. (author), Geiker, Mette R. (author), Alonso, Maria Cruz (author), Polder, R.B. (author), Elsener, Bernhard (author), Wong, Hong (author), Michel, Alexander (author), Hornbostel, Karla (author), Sanchez, Mercedes (author)
The steel–concrete interface (SCI) is known to influence corrosion of steel in concrete. However, due to the numerous factors affecting the SCI—including steel properties, concrete properties, execution, and exposure conditions—it remains unclear which factors have the most dominant impact on the susceptibility of reinforced concrete to...
review 2019
document
Angst, Ueli M. (author), Geiker, Mette R. (author), Michel, Alexander (author), Gehlen, Christoph (author), Wong, Hong (author), Isgor, O. Burkan (author), Elsener, Bernhard (author), Hansson, Carolyn M. (author), François, Raoul (author), Hornbostel, Karla (author), Polder, R.B. (author), Alonso, Maria Cruz (author), Sanchez, Mercedes (author), Correia, Maria João (author), Criado, Maria (author), Sagüés, A. (author), Buenfeld, Nick (author)
Although the steel–concrete interface (SCI) is widely recognized to influence the durability of reinforced concrete, a systematic overview and detailed documentation of the various aspects of the SCI are lacking. In this paper, we compiled a comprehensive list of possible local characteristics at the SCI and reviewed available information...
journal article 2017