Searched for: subject%3A%22prosthetic%255C+hand%22
(1 - 9 of 9)
document
Bierbaum, S. (author)
Myoelectric as well as body-powered hand prostheses, the two commercially available prosthetic control types, have both their specific advantages. Advanced myoelectric prostheses for example have the characteristic of facilitating multiple degrees of freedom due to grip type variation and/or wrist movements. Compared to prosthetic devices with...
master thesis 2017
document
Maat, B.B. (author)
Master-thesis work on the design and evaluation of an adaptive passive hand prosthesis, with a novel control method.
master thesis 2015
document
Versluis, E.W.L. (author)
Body Powered Hand Prostheses provide the user with a replacement for a missing hand. Current body powered hand prostheses are inefficient and require large input forces for the control. Improvements are needed to provide amputees with adequate body powered hand prostheses. The Delft Cylinder Hand, a promising design for an underactuated...
master thesis 2015
document
Smit, G. (author), Plettenburg, D.H. (author), Van der Helm, F.C.T. (author)
Rejection rates of upper limb prostheses are high (23-45%). Amputees indicate that the highest design priority should be reduction of the mass of the prosthetic device. Despite all efforts, the mass of the new prosthetic hands is 35-73% higher than that of older hands. Furthermore current hands are thicker than a human hand, they operate slower...
journal article 2014
document
Smit, G. (author), Plettenburg, D.H. (author)
Current articulating electric and body-powered hands have a lower pinch force (15–34 N) than electric hands with stiff fingers (55–100 N). The cosmetic glove, which covers a hand prosthesis, negatively affects the mechanical efficiency of a prosthesis. The goal of this study is to mechanically compare polyvinylchloride (PVC) and silicone...
journal article 2013
document
Smit, G. (author)
Replacement of a missing hand by an artificial alternative remains one of the biggest challenges in rehabilitation. Although many different terminal devices are available, around 27% of the amputees does not actively use their device and 20% totally refrains from wearing it. There are various reasons for prosthesis abandonment, e.g. wearing...
doctoral thesis 2013
document
Smit, G. (author), Bongers, R.M. (author), Van der Sluis, C.K. (author), Plettenburg, D.H. (author)
Quantitative data on the mechanical performance of upper-limb prostheses are very important in prostheses development and selection. The primary goal of this study was to objectively evaluate the mechanical performance of adult-size voluntary opening (VO) prosthetic terminal devices and select the best tested device. A second goal was to see...
journal article 2012
document
Hekman, E.E.G. (author)
Rapport Nr. N-270 - Handprothesen worden vaak bedekt met een cosmetische handschoen om op deze manier de kunsthand een zo natuurlijk mogelijk voorkomen te geven. Een nadeel van deze handschoen i s echter dat deze bij het openen van de kunsthand een tegenwerkend koppel levert. Om deze tegenwerking op te heffen wordt gezocht naar een mechanisme...
master thesis 1986
document
Danz, M.H. (author)
In deze skriptie worden resultaten uit de literatuur op het gebied van de mechanische belastbaarheid van de menselijke huid behandeld. Daarbij wordt alleen gekeken naar die belastinggevallen, waarvan verwacht kan worden dat ze bij het dragen van pro- en orthesen zullen voorkomen: drukkracht (eventueel negatief) loodrecht op de huid en...
report 1985
Searched for: subject%3A%22prosthetic%255C+hand%22
(1 - 9 of 9)