Searched for: subject%3A%22self%255C+calibration%22
(1 - 5 of 5)
document
van de Ven, Oscar S. (author), Vogel, J.G. (author), Xia, Sha (author), Spronck, J.W. (author), Nihtianova, S. (author)
High-precision positioning often requires high speed and high resolution displacement measurements in order to compensate for the small vibrations of critical components. The displacement sensor must be precise and stable over a long period of time to avoid expensive recalibration. This requires tight mounting tolerances, which are especially...
journal article 2018
document
Chen, Peng (author), Huang, Xiongchuan (author), Chen, Y. (author), Wu, Lianbo (author), Staszewski, R.B. (author)
To characterize an on-chip programmable delay in a low-cost and high-resolution manner, a built-in self-test based on a first-order ΔΣ time-to-digital converter with self-calibration is proposed and implemented in TSMC 28-nm CMOS. The system is self-contained, and only one digital clock is needed for the measurements. A...
journal article 2018
document
Nambur Ramamohan, K. (author), Chepuri, S.P. (author), Comesana, Daniel Fernandez (author), Pousa, Graciano Carrillo (author), Leus, G.J.T. (author)
In this paper, we present a calibration algorithm for acoustic vector sensors arranged in a uniform linear array configuration. To do so, we do not use a calibrator source, instead we leverage the Toeplitz blocks present in the data covariance matrix. We develop linear estimators for estimating sensor gains and phases. Further, we discuss the...
conference paper 2018
document
Massaad Mouawad, J.M. (author), van Neer, P.L.M.J. (author), van Willigen, D.M. (author), Pertijs, M.A.P. (author), de Jong, N. (author), Verweij, M.D. (author)
Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe...
journal article 2022
document
Nambur Ramamohan, K. (author)
Microphones are the most popular devices used to convert sound into electrical signals. However, with the advent of sensor technology, transducers capable of measuring vector quantities are opening up many new possibilities. One such device is an acoustic vector sensor (AVS), which measures both acoustic pressure and particle velocity, and has...
doctoral thesis 2022
Searched for: subject%3A%22self%255C+calibration%22
(1 - 5 of 5)