XX
Xiao Yun Xu
8 records found
1
This study aimed to characterize the altered hemodynamics and wall mechanics in ascending thoracic aortic aneurysms (ATAA) by employing fully coupled two-way fluid–structure interaction (FSI) analyses. Our FSI models incorporated hyperelastic wall mechanical properties, prestress
...
Background: Bioprosthetic aortic valves (BPAV) have been increasingly used for surgical aortic valve replacement (SAVR), but long-term complications associated with structural valve deterioration remain a concern. The structural behaviour of the valve and its surrounding haemodyn
...
The normal healthy aortic valve (AoV) has three leaflets, two of which have outflows to the coronary arteries. Blood flow through the coronary ostia will have an impact on AoV dynamics and the surrounding haemodynamics, leading to differential shear stress distributions at the ao
...
Purpose: Finite element analysis (FEA) has been used to predict wall stress in ascending thoracic aortic aneurysm (ATAA) in order to evaluate risk of dissection or rupture. Patient-specific FEA requires detailed information on ATAA geometry, loading conditions, material propertie
...
The opening and closing dynamics of the aortic valve (AV) has a strong influence on haemodynamics in the aortic root, and both play a pivotal role in maintaining normal physiological functions of the valve. The aim of this study was to establish a subject-specific fluid–structure
...
Aortic valve neocuspidization and bioprosthetic valves
Evaluating turbulence haemodynamics
Aortic valve disease is often treated with bioprosthetic valves. An alternative treatment is aortic valve neocuspidization which is a relatively new reparative procedure whereby the three aortic cusps are replaced with patient pericardium or bovine tissues. Recent research indica
...
Background and Objective: Numerical simulations of blood flow are a valuable tool to investigate the pathophysiology of ascending thoratic aortic aneurysms (ATAA). To accurately reproduce in vivo hemodynamics, computational fluid dynamics (CFD) models must employ realistic inflow
...
Introduction: Thoracic endovascular aortic repair (TEVAR) of the arch is challenging given its complex geometry and the involvement of supra-aortic arteries. Different branched endografts have been designed for use in this region, but their haemodynamic performance and the risk f
...