F. F.S. van der Tak
Please Note
7 records found
1
We report a high accuracy pointing technique for quasi-optical hot electron bolometer (HEB) mixers in focal-plane arrays designed to operate at 1.4, 1.9, and 4.7 THz. The high accuracy pointing is achieved by prealignment of a HEB chip to a lens, measuring the angular error of each mixer in an array assembly, and then realignment of the chip to the same lens to correct the error. The realigned mixers, using 5 mm diameter Si elliptical lenses designed for operation at 4.7 THz, show a final pointing error distribution with an average (μ) = 0.13° and standard deviation (σ) = 0.06°, with respect to the normal direction of the respective array plane. Those using 10 mm diameter lenses designed for operation either at 1.4 or 1.9 THz, show μ = 0.08° and σ = 0.03°. We demonstrated our pointing technique in five 4×2 HEB focal plane arrays developed for NASA's balloon borne GUSTO THz observatory. Our results corroborate the simulated beam steering factors used to calculate the realignment corrections. With the unprecedented pointing accuracy at the high frequencies, our technique can significantly facilitate the use of lens-antenna, quasi-optical mixers for future focal-plane arrays, which is able to compete with traditional feedhorn-waveguide mixer arrays, operated typically below 1 THz, for astronomical instrumentation.
We have characterized and mapped the electrical cross talk (ECT) of a frequency division multiplexing (FDM) system with a transition edge sensor (TES) bolometer array, which is intended for space applications. By adding a small modulation at 120 Hz to the AC bias voltage of one bolometer and measuring the cross talk response in the current noise spectra of the others simultaneously, we have for the first time mapped the ECT level of 61 pixels with a nominal frequency spacing of 32 kHz in a 61 × 61 matrix and a carrier frequency ranging from 1 MHz to 4 MHz. We find that about 94% of the pixels show an ECT level of less than 0.4%. Only the adjacent pixels reach this level, and the ECT for the rest of the pixels is less than 0.1%. We also observe higher ECT levels, up to 10%, between some of the pixels, which have bundled long, parallel coplanar wires connecting TES bolometers to inductor-capacitor filters. In this case, the high mutual inductances dominate. To mitigate this source of ECT, the coplanar wires should be replaced by microstrip wires in the array. Our study suggests that an FDM system can have a relatively low ECT level, e.g., around 0.4% if the frequency spacing is 30 kHz. Our results successfully demonstrate a low electrical cross talk for a space FDM technology.
We have demonstrated a low noise superconducting MgB2 hot electron bolometer (HEB) mixer working at the frequency of 5.3 terahertz (THz) with 20 K operation temperature. The bolometer consists of a 7 nm thick MgB2 submicrometer bridge contacted with a spiral antenna to couple THz radiation through a high resistive Si lens, and it has a superconducting critical temperature of 38 K. By using hot/cold blackbody loads and a Mylar beam splitter all in vacuum and applying a 5.25 THz far-infrared gas laser as a local oscillator, we measured a minimal double sideband receiver noise temperature of 3960 K at the LO power of 9.5 μW. This can be further reduced to 2920 K if a Si lens with an antireflection coating optimized at this frequency and a 3 μm beam splitter are used. The measured intermediate frequency (IF) noise bandwidth is 9.5 GHz. The low noise, wide IF bandwidth mixers, which can be operated in a compact, low dissipation Stirling cooler, are more suitable for space applications than the existing HEB mixers. Furthermore, we likely observed a signature of the double-gap in MgB2 by comparing current-voltage curves pumped at 5.3 and 1.6 THz.
The SPICA-SAFARI instrument requires extremely sensitive transition edge sensor (TES) arrays with a noise equivalent power of 2×10-19W/Hz and a readout system with an output noise that is dominated by the detector noise. It is essential to ensure the frequency domain multiplexing (FDM) readout system in SAFARI meets the noise requirement. The FDM system in SAFARI consists essentially of LC filters, a superconducting quantum interference device, a room-temperature low-noise amplifier (LNA), and a demultiplexer. Here we present a noise study of the LNA from a laboratory amplifier chain. We found the equivalent current and voltage noise of the LNA to be 5.4pA/Hz and 315pV/Hz, respectively, which are low enough to read out SAFARI’s TES arrays.
Large heterodyne receiver arrays (~100 pixel) allow astronomical instrumentations mapping more area within limited space mission lifetime. One challenge is to generate multiple local oscillator (LO) beams. Here, We succeeded in generating 81 beams at 3.86 THz by combining a reflective, metallic Fourier grating with an unidirectional antenna coupled 3rd-order distributed feedback (DFB) quantum cascade laser (QCL). We have measured the diffracted 81 beams by scanning a single pyroelectric detector at a plane, which is in the far field for the diffraction beams. The measured output beam pattern agrees well with a simulated result from COMSOL Multiphysics with respect to the angular distribution and power distribution among the 81 beams. We also derived the diffraction efficiency to be 94\pm 3\%, which is very close to what was simulated for a manufactured Fourier grating (97%). For an array of equal superconducting hot electron bolometer mixers, 64 out of 81 beams can pump the HEB mixers with similar power, resulting in receiver sensitivities within 10%. Such a combination of a Fourier grating and a QCL can create an LO with 100 beams or more, enabling a new generation of large heterodyne arrays for astronomical instrumentation. This paper is essentially a copy of our paper in Optics Express.
We present observations of the Trumpler 14/Carina I region carried out using the Stratospheric Terahertz Observatory 2. The Trumpler 14/Carina I region is in the western part of the Carina Nebula Complex (CNC), which is one of the most extreme star-forming regions in the Milky Way. We observed Trumpler 14/Carina I in the 158 μm transition of [C ii] with a spatial resolution of 48″ and a velocity resolution of 0.17 km s-1. The observations cover a 0.25 by 0.28 area with central position l = 297.34, b = -0.60. The kinematics show that bright [C ii] structures are spatially and spectrally correlated with the surfaces of CO clouds, tracing the photodissociation region (PDR) and ionization front of each molecular cloud. Along seven lines of sight (LOSs) that traverse Tr 14 into the dark ridge to the southwest, we find that the [C ii] luminosity from the H ii region is 3.7 times that from the PDR. In the same LOS, we find in the PDRs an average ratio of 1 : 4.1 : 5.6 for the mass in atomic gas : dark CO gas : molecular gas traced by CO. Comparing multiple gas tracers, including H i 21 cm, [C ii], CO, and radio recombination lines, we find that the H ii regions of the CNC are well described as H ii regions with one side freely expanding toward us, consistent with the Champagne model of ionized gas evolution. The dispersal of the GMC in this region is dominated by EUV photoevaporation; the dispersal timescale is 20-30 Myr.
Large heterodyne receiver arrays (~100 pixel) allow astronomical instrumentations to map more area within limited space mission lifetime. One challenge is to generate multiple local oscillator (LO) beams. Here, we succeeded in generating 81 beams at 3.86 THz by combining a reflective, metallic Fourier grating with an unidirectional antenna coupled 3rd-order distributed feedback (DFB) quantum cascade laser (QCL). We have measured the diffracted 81 beams by scanning a single pyroelectric detector at a plane, which is in the far field for the diffraction beams. The measured output beam pattern agrees well with a simulated result from COMSOL Multiphysics, with respect to the angular distribution and power distribution among the 81 beams. We also derived the diffraction efficiency to be 94 ± 3%, which is very close to what was simulated for a manufactured Fourier grating (97%). For an array of equal superconducting hot electron bolometer mixers, 64 out of 81 beams can pump the HEB mixers with similar power, resulting in receiver sensitivities within 10%. Such a combination of a Fourier grating and a QCL can create an LO with 100 beams or more, enabling a new generation of large heterodyne arrays for astronomical instrumentation.