The impact of hydraulic model calibration on model-based leak localization accuracy
Conclusions drawn from a real-world case study
Conference paper
(2019)
-
Jakim P. Lippacher, David B. Steffelbauer, Georg Arbesser-Rastburg, Daniela Fuchs-Hanusch
This study examines the influence of the quality of hydraulic model calibration on the accuracy of model-based leak localization. It is based on a real-world case study where pressures were measured at 12 positions for more than 4 months. Fire flow tests were performed to obtain calibration data—artificially generated leaks with different sizes between 0.25 l/s to 1 l/s at 4 different positions served as dataset for model-based leak localization. Three different calibration approaches were applied on an uncalibrated model generated from GIS data: (i) height adjustments of measurement positions through detailed analysis of long term pressure signals in the leak-free system; as well as (ii) manual trial and error calibration; and (iii) automatic calibration with fire flow test data. The height-adjusted model lead to increased leak localization accuracy compared to the uncalibrated GIS model. However, the most significant improvement was achieved through fire flow test based calibration—revealing a partially closed valve in the system. The auto-calibrated model, which simultaneously calibrated roughness and minor loss coefficients, provided the highest leak localization accuracy.
...
This study examines the influence of the quality of hydraulic model calibration on the accuracy of model-based leak localization. It is based on a real-world case study where pressures were measured at 12 positions for more than 4 months. Fire flow tests were performed to obtain calibration data—artificially generated leaks with different sizes between 0.25 l/s to 1 l/s at 4 different positions served as dataset for model-based leak localization. Three different calibration approaches were applied on an uncalibrated model generated from GIS data: (i) height adjustments of measurement positions through detailed analysis of long term pressure signals in the leak-free system; as well as (ii) manual trial and error calibration; and (iii) automatic calibration with fire flow test data. The height-adjusted model lead to increased leak localization accuracy compared to the uncalibrated GIS model. However, the most significant improvement was achieved through fire flow test based calibration—revealing a partially closed valve in the system. The auto-calibrated model, which simultaneously calibrated roughness and minor loss coefficients, provided the highest leak localization accuracy.