Instrumental intelligibility metrics are commonly used as an alternative to listening tests. This paper evaluates 12 monaural intrusive intelligibility metrics: SII, HEGP, CSII, HASPI, NCM, QSTI, STOI, ESTOI, MIKNN, SIMI, SIIB, and sEPSMcorr. In addition, this paper investigates ...
Instrumental measures of speech intelligibility typically produce an index between 0 and 1 that is monotonically related to listening test scores. As such, these measures are dimensionless and do not represent physical quantities. In this paper, we propose a new instrumental inte ...
We propose a monaural intrusive instrumental intelligibility metric called SIIB (speech intelligibility in bits). SIIB is an estimate of the amount of information shared between a talker and a listener in bits per second. Unlike existing information theoretic intelligibility metr ...
The key to the success of speech-based technology is an understanding of human speech communication. While significant advances have been made, a unified theory of speech communication that is both comprehensive and quantitative is yet to emerge. In this paper we approach speech ...