The use of a single set of outriggers equipped with oil viscous dampers increases the damping ratio of tall buildings in about 6–10%, depending on the loading conditions. However, could this ratio be further increased by the addition of another set of outriggers? Should this addi ...
The seismic design of optimal damped outrigger structures relies on the assumption that most of the input energy will be absorbed by the dampers, whilst the rest of the structure remains elastic. When subjected to strong earthquakes, nevertheless, the building structure may exhib ...
This article provides an analytical framework to assess the distribution of seismic energy in outrigger structures equipped with viscous dampers. The principle of damped outriggers for seismic control applications lies on the assumption that the total earthquake energy will be ab ...

Contributed

1 records found

Smart Energy Dissipation

Damped Outriggers for Tall Buildings under Strong Earthquakes

The use of outriggers in tall buildings is a common practice to reduce response under dynamic loading. Viscous dampers have been implemented between the outrigger and the perimeter columns, to reduce vibrations produced by strong winds. However, its behaviour under strong earthqu ...