Operating a body-powered prosthesis can be painful and tiring due to high cable operation forces, illustrating that low cable operation forces are a desirable design property for body-powered prostheses. However, lower operation forces might negatively affect controllability and force perception, which is plausible but not known. This study aims to quantify the accuracy of cable force perception and control for body-powered prostheses in a low cable operation force range by utilizing isometric and dynamic force reproduction experiments. Twenty-five subjects with trans-radial absence conducted two force reproduction tasks; first an isometric task of reproducing 10, 15, 20, 25, 30 or 40 N and second a force reproduction task of 10 and 20 N, for cable excursions of 10, 20, 40, 60 and 80 mm. Task performance was quantified by the force reproduction error and the variability in the generated force. The results of the isometric experiment demonstrated that increasing force levels enlarge the force variability, but do not influence the force reproduction error for the tested force range. The second experiment showed that increased cable excursions resulted in a decreased force reproduction error, for both tested force levels, whereas the force variability remained unchanged. In conclusion, the design recommendations for voluntary closing body-powered prostheses suggested by this study are to minimize cable operation forces: this does not affect force reproduction error but does reduce force variability. Furthermore, increased cable excursions facilitate users with additional information to meet a target force more accurately.
Background: Body-powered prostheses require cable operation forces between 33 and 131 N. The accepted upper limit for fatigue-free long-duration operation is 20% of a users’ maximum cable operation force. However, no information is available on users’ maximum force. Objectives: To quantify users’ maximum cable operation force and to relate this to the fatigue-free force range for the use of body-powered prostheses. Study design: Experimental trial. Methods: In total, 23 subjects with trans-radial deficiencies used a bypass prosthesis to exert maximum cable force three times during 3 s and reported discomfort or pain on a body map. Additionally, subjects’ anthropometric measures were taken to relate to maximum force. Results: Subjects generated forces ranging from 87 to 538 N. Of the 23 subjects, 12 generated insufficient maximum cable force to operate 8 of the 10 body-powered prostheses fatigue free. Discomfort or pain did not correlate with the magnitude of maximum force achieved by the subjects. Nine subjects indicated discomfort or pain. No relationships between anthropometry and maximal forces were found except for maximum cable forces and the affected upper-arm circumference for females. Conclusion: For a majority of subjects, the maximal cable force was lower than acceptable for fatigue-free prosthesis use. Discomfort or pain occurred in ~40% of the subjects, suggesting a suboptimal force transmission mechanism. Clinical relevance: The physical strength of users determines whether a body-powered prosthesis is suitable for comfortable, fatigue-free long-duration use on a daily basis. High cable operation forces can provoke discomfort and pain for some users, mainly in the armpit. Prediction of the users’ strength by anthropometric measures might assist the choice of a suitable prosthesis.
Background: The accuracy of source reconstruction depends on the spatial configuration of the neural sources underlying encephalographic signals, the temporal distance of the source activity, the level and structure of noise in the recordings, and – of course – on the employed inverse method. This plenitude of factors renders a definition of ‘spatial resolution’ of the electro-encephalogram (EEG) a challenge. New method: A proper definition of spatial resolution requires a ground truth. We used data from numerical simulations of two dipoles changed with waveforms resembling somatosensory evoked potentials peaking at 20, 30, 50, 100 ms. We varied inter-dipole distances and added noise to the simulated scalp recordings with distinct signal-to-noise ratios (SNRs). Prior to inverse modeling we pre-whitened the simulated data and the leadfield. We tested a two-dipole fit, sc-MUSIC, and sc-eLORETA and assessed their accuracy via the distance between the simulated and estimated sources. Results: To quantify the spatial resolution of EEG, we introduced the notion of separability, i.e. the separation of two dipolar sources with a certain inter-dipole distance. Our results indicate separability of two sources in the presence of realistic noise with SNR up to 3 if they are 11 mm or further apart. Comparison with existing methods: In the presence of realistic noise, spatial pre-whitening appears mandatory preprocessing step irrespective of the inverse method employed. Conclusions: Separability is a legitimate measure to quantify EEG's spatial resolution. An optimal resolution in source reconstruction requires spatial pre-whitening as a crucial pre-processing step.
frequency, indicating nonlinear behavior. Even though the selection of analysis techniques depends on the linearity of the system under study, the importance of nonlinear contributions to cortical responses has not been formally
addressed.The goal of this paper is to quantify the nonlinear contributions to the cortical response obtained fromcontinuous sensory stimulation. EEG was used to record the cortical response evoked by continuousmovement of the wrist joint of healthy subjects applied with a robotic manipulator. Multisine stimulus signals (i.e., the sum of several sinusoids) elicit a periodic cortical response and allowto assess
the nonlinear contributions to the response.Wrist dynamics (relation between joint angle and torque) were successfully linearized, explaining 99% of the response. In contrast, the cortical response revealed a highly nonlinear relation;
where most power ( ∼ 80%) occurred at non-stimulated frequencies. Moreover, only 10% of the response could be explained using a nonparametric linear model. These results indicate that the recorded evoked cortical responses
are governed by nonlinearities and that linear methods do not suffice when describing the relation between mechanical stimulus and cortical response. ...
frequency, indicating nonlinear behavior. Even though the selection of analysis techniques depends on the linearity of the system under study, the importance of nonlinear contributions to cortical responses has not been formally
addressed.The goal of this paper is to quantify the nonlinear contributions to the cortical response obtained fromcontinuous sensory stimulation. EEG was used to record the cortical response evoked by continuousmovement of the wrist joint of healthy subjects applied with a robotic manipulator. Multisine stimulus signals (i.e., the sum of several sinusoids) elicit a periodic cortical response and allowto assess
the nonlinear contributions to the response.Wrist dynamics (relation between joint angle and torque) were successfully linearized, explaining 99% of the response. In contrast, the cortical response revealed a highly nonlinear relation;
where most power ( ∼ 80%) occurred at non-stimulated frequencies. Moreover, only 10% of the response could be explained using a nonparametric linear model. These results indicate that the recorded evoked cortical responses
are governed by nonlinearities and that linear methods do not suffice when describing the relation between mechanical stimulus and cortical response.
We suggest short range stiffness (SRS) at the elbow joint as an alternative diagnostic for EMG to assess cocontraction.Elbow SRS is compared between obstetric brachial plexus lesion (OBPL) patients and healthy subjects (cross-sectional study design). Seven controls (median 28. years) and five patients (median 31. years) isometrically flexed and extended the elbow at rest and three additional torques [2.1,. 4.3,. 6.4. N. m] while a fast stretch stimulus was applied. SRS was estimated in silico using a neuromechanical elbow model simulating the torque response from the imposed elbow angle.SRS was higher in patients (250. ±. 36. N. m/rad) than in controls (150. ±. 21. N. m/rad, p = 0.014), except for the rest condition. Higher elbow SRS suggested greater cocontraction in patients compared to controls. SRS is a promising mechanical alternative to assess cocontraction, which is a frequently encountered clinical problem in OBPL due to axonal misrouting.