Journal article (2024) - J. Bloemberg, B. Hoppener, Bram Coolen, A. Sakes, P. Breedveld
Transperineal laser ablation is a minimally invasive thermo-ablative treatment for prostate cancer that requires the insertion of a needle for accurate optical fiber positioning. Needle insertion in soft tissues may cause tissue motion and deformation, resulting in tissue damage and needle positioning errors. In this study, we present a wasp-inspired self-propelled needle that uses pneumatic actuation to move forward with zero external push force, thus avoiding large tissue motion and deformation. The needle consists of six parallel 0.25-mm diameter Nitinol rods driven by a pneumatic actuation system. The pneumatic actuation system consists of Magnetic Resonance (MR) safe 3D-printed parts and off-the-shelf plastic screws. A self-propelled motion is achieved by advancing the needle segments one by one, followed by retracting them simultaneously. The advancing needle segment has to overcome a cutting and friction force, while the stationary needle segments experience a friction force in the opposite direction. The needle self-propels through the tissue when the friction force of the five stationary needle segments overcomes the sum of the friction and cutting forces of the advancing needle segment. We evaluated the prototype’s performance in 10-wt% gelatin phantoms and ex vivo porcine liver tissue inside a preclinical Magnetic Resonance Imaging (MRI) scanner in terms of the slip ratio of the needle with respect to the phantom or liver tissue. Our results demonstrated that the needle was able to self-propel through the phantom and liver tissue with slip ratios of 0.912–0.955 and 0.88, respectively. The prototype is a promising step toward the development of self-propelled needles for MRI-guided transperineal laser ablation as a method to treat prostate cancer. ...
Journal article (2022) - J. Bloemberg, F. Trauzettel, Bram F. Coolen, D. Dodou
Prostate cancer diagnosis and focal laser ablation treatment both require the insertion of a needle for biopsy and optical fibre positioning. Needle insertion in soft tissues may cause tissue motion and deformation, which can, in turn, result in tissue damage and needle positioning errors. In this study, we present a prototype system making use of a wasp-inspired (bioinspired) self-propelled needle, which is able to move forward with zero external push force, thereby avoiding large tissue motion and deformation. Additionally, the actuation system solely consists of 3D printed parts and is therefore safe to use inside a magnetic resonance imaging (MRI) system. The needle consists of six parallel 0.25-mm diameter Nitinol rods driven by the actuation system. In the prototype, the self-propelled motion is achieved by advancing one needle segment while retracting the others. The advancing needle segment has to overcome a cutting and friction force while the retracting needle segments experience a friction force in the opposite direction. The needle self-propels through the tissue when the friction force of the five retracting needle segments overcomes the sum of the friction and cutting forces of the advancing needle segment. We tested the performance of the prototype in ex vivo human prostate tissue inside a preclinical MRI system in terms of the slip ratio of the needle with respect to the prostate tissue. The results showed that the needle was visible in MR images and that the needle was able to self-propel through the tissue with a slip ratio in the range of 0.78–0.95. The prototype is a step toward self-propelled needles for MRI-guided transperineal laser ablation as a method to treat prostate cancer. ...
Journal article (2021) - Lukas M. Gottwald, Carmen P.S. Blanken, João Tourais, Jouke Smink, R. Nils Planken, S. Matthijs Boekholdt, Lilian J. Meijboom, Bram F. Coolen, Gustav J. Strijkers, More Authors...
Background: Respiratory gating is generally recommended in 4D flow MRI of the heart to avoid blurring and motion artifacts. Recently, a novel automated contact-less camera-based respiratory motion sensor has been introduced. Purpose: To compare camera-based respiratory gating (CAM) with liver-lung-navigator-based gating (NAV) and no gating (NO) for whole-heart 4D flow MRI. Study Type: Retrospective. Subjects: Thirty two patients with a spectrum of cardiovascular diseases. Field Strength/Sequence: A 3T, 3D-cine spoiled-gradient-echo-T1-weighted-sequence with flow-encoding in three spatial directions. Assessment: Respiratory phases were derived and compared against each other by cross-correlation. Three radiologists/cardiologist scored images reconstructed with camera-based, navigator-based, and no respiratory gating with a 4-point Likert scale (qualitative analysis). Quantitative image quality analysis, in form of signal-to-noise ratio (SNR) and liver-lung-edge (LLE) for sharpness and quantitative flow analysis of the valves were performed semi-automatically. Statistical Tests: One-way repeated measured analysis of variance (ANOVA) with Wilks's lambda testing and follow-up pairwise comparisons. Significance level of P ≤ 0.05. Krippendorff's-alpha-test for inter-rater reliability. Results: The respiratory signal analysis revealed that CAM and NAV phases were highly correlated (C = 0.93 ± 0.09, P < 0.01). Image scoring showed poor inter-rater reliability and no significant differences were observed (P ≥ 0.16). The image quality comparison showed that NAV and CAM were superior to NO with higher SNR (P = 0.02) and smaller LLE (P < 0.01). The quantitative flow analysis showed significant differences between the three respiratory-gated reconstructions in the tricuspid and pulmonary valves (P ≤ 0.05), but not in the mitral and aortic valves (P > 0.05). Pairwise comparisons showed that reconstructions without respiratory gating were different in flow measurements to either CAM or NAV or both, but no differences were found between CAM and NAV reconstructions. Data Conclusion: Camera-based respiratory gating performed as well as conventional liver-lung-navigator-based respiratory gating. Quantitative image quality analysis showed that both techniques were equivalent and superior to no-gating-reconstructions. Quantitative flow analysis revealed local flow differences (tricuspid/pulmonary valves) in images of no-gating-reconstructions, but no differences were found between images reconstructed with camera-based and navigator-based respiratory gating. Level of Evidence: 3. Technical Efficacy: Stage 2. ...