Introduction: Bone fractures represent a global health problem with the incidence of fractures on the rise each year. The predominant method for addressing bone fractures involves immobilization. Worldwide, many initiatives have sought to develop innovative fracture immobilization designs, and numerous solutions have been patented. However, a comprehensive overview and systematic classification of these patented designs is lacking. Areas covered: In pursuit of these patented immobilization designs, the Espacenet database, recognized as the largest global repository of patents, served as the principal investigative tool. Using a search string, patent classifications and inclusion criteria a total of 71 patents were identified. These can be classified into four unique design groups: (1) fixed and partly enclosed, (2) fixed and fully enclosed, (3) adjustable and partly enclosed and (4) adjustable and fully enclosed designs. The designs that are commercially available are predominantly situated within groups 3 and 4. Expert opinion: Advances in 3D scanning and additive manufacturing could improve comfort, personalization, and monitoring in fracture immobilization, but clinical adoption is hindered by slow production times, workflow misalignment, and regulatory barriers. Key improvements are needed in scanning accuracy, adjustment protocols, and integration into hospital logistics to ensure both technical feasibility and clinical usability. ...

A State-of-the-Art Review

Bamboo, known for its unique mechanical and antibacterial properties, has attracted growing interest as a sustainable material for medical applications. Despite its potential, its adoption in modern clinical settings remains limited. This review aims to provide a comprehensive overview of current medical uses of bamboo-based materials, focusing on application areas and material composition. A systematic literature search across the PubMed and Scopus databases yielded 45 relevant articles. These were categorized according to medical application and material utilization. Bamboo medical devices exhibited greater variability; those used inside the body often incorporated bamboo as a significant structural element, whereas external devices typically used bamboo as reinforcement. Textiles for treatment primarily used bamboo as a minor component, often combined with antimicrobial or mechanical strengthening agents. In contrast, protective textiles used bamboo primarily as a significant component, leveraging its inherent comfort and breathability. Across all applications, bamboo was selected for its mechanical, antimicrobial, and breathable characteristics. The integration of bamboo in medical technologies is growing, driven by its sustainability and functional performance. However, challenges remain in processing complexity and in demonstrating clear advantages over conventional materials. ...
Flexible biopsy needles are essential for minimally invasive cancer diagnostics, enabling core biopsy sampling through endoscopic and catheter-based procedures. These approaches allow clinicians to access deep-seated or anatomically challenging lesions while reducing patient risk compared to traditional percutaneous methods. However, the shift toward minimally invasive techniques imposes competing design demands on the biopsy needle tip, which must be miniaturized and flexible enough to navigate narrow lumens while maintaining cutting efficiency and retaining adequate tissue samples for clinical diagnosis. This review presents a patent-based analysis of flexible core biopsy needle designs, focusing on mechanisms at the needle tip that govern tissue cutting and retention. We systematically evaluated 65 international patent applications and developed a classification framework for cutting and gripping strategies. Using this framework, we identified dominant technological trends and highlighted underexplored concepts. Forward-cutting tips combined with suction or macroshape grips that engage the sample from the front dominate current designs due to their mechanical simplicity. However, alternative approaches such as compliant tip designs and multidirectional cutting mechanisms offer opportunities to enhance tissue yield without increasing device diameter. Implementing these innovations could reduce the need for repeated insertions, improve sampling efficiency, and enable access to lesions previously considered unreachable. This review provides an overview of flexible core biopsy needle designs and offers insights to guide future innovations that advance minimally invasive cancer diagnostics. ...
Review (2025) - Łucja Aleksandra Żurawska, Frank Gijsen, Pieter Jan van Doormaal, Paul Breedveld
Introduction: Thromboembolic conditions are a leading global cause of mortality and a major cause of disability. Throughout the years mechanical thrombectomy has become a preferred method of treatment. Removing thrombus in its entirety on first pass decreases procedure time as well as lowers the risk of distal embolization. Areas covered: This review provides a comprehensive overview and classification of the patent literature on devices for non-fragmented thrombus removal via grip. Patentscope database was used to search for internationally granted patents published any time before the access date (October 2024). The search using keywords and patent classification code led to identifying 141 relevant patents that were then categorized based on location and type of grip they describe. Expert opinion: The designs found are analyzed in the discussion and a broader context for their relevance is given in the expert opinion section. The following review can provide insight into possible mechanical thrombectomy methods, general trends in the field as well as serve as an inspiration in development of novel devices. ...
Journal article (2025) - J. Bloemberg, M. van der Wel, A. Sakes, P. Breedveld
In percutaneous interventions, long and thin needles are used to reach deep target locations within the body. However, inserting a long and thin needle into the tissue can cause needle buckling, resulting in poor control of the needle’s trajectory and reduced targeting accuracy. In nature, the female parasitic wasp prevents the buckling of her long and slender ovipositor through a self-propelled motion. This study presents a stationary actuation system that can advance a wasp-inspired self-propelled needle consisting of seven 0.3-mm stainless steel rods with a theoretically unlimited insertion length. Based on the pencil lead advance mechanism in mechanical pencils that advances the pencil lead at a fixed increment when the pencil button is pushed, our actuation system advances the seven needle segments that comprise our needle by locking, advancing, releasing, and retracting the advance mechanisms. Experimental evaluation demonstrated that the actuation system successfully executes these actions, enabling step-by-step propulsion of the needle segments in gelatin-based tissue-mimicking phantoms. Moreover, the needle achieved mean motion efficiencies of 98 ± 2%, 68 ± 5%, and 57 ± 7% in air, 5-wt% gelatin, and 10-wt% gelatin, respectively, over 15 actuation cycles. This actuation system prototype, which is based on a mechanical pencil, is a step forward in developing self-propelled needles for targeting deep tissue structures. ...
Journal article (2025) - E.P. de Kater, T.G. Kaptijn, P. Breedveld, A. Sakes
Orthopedic surgery relies on bone drills to create tunnels for fracture fixation, bone fusion, or tendon repair. Traditional rigid and straight bone drills often pose challenges in accessing the desired entry points without risking damage to the surrounding anatomical structures, especially in minimal invasive procedures. In this study, we explore the use of hydraulic pressure waves in a flexible bone design to facilitate bone drilling. The HydroFlex Drill includes a handle for generating a hydraulic pressure wave in the flexible, fluid-filled shaft to transmit an impulse to the hammer tip, enabling bone drilling. We evaluated seven different hammer tip shapes to determine their impact on drilling efficiency. Subsequently, the most promising tip was implemented in the HydroFlex Drill. The HydroFlex Drill Validation demonstrated the drill's ability to successfully transfer the impulse generated in the handle to the hammer tip, with the shaft in different curves. This combined with the drill's ability to create indentations in bone phantom material is a promising first step towards the development of a flexible or even steerable bone drill. With ongoing research to enhance the drilling efficiency, the HydroFlex Drill opens possibilities for a range of orthopedic surgical procedures where minimally invasive drilling is essential. ...
Introduction: Orthopedic procedures often require drilling of tunnels through bone, for instance for the introduction of implants. The currently used rigid bone drills make it challenging to reach all target areas without damaging surrounding anatomy. Steerable bone drills are a promising solution as they enable access to larger volumes and the creation of curved tunnels thereby reducing the risk of harm to surrounding anatomical structures.

Method: This review provides a comprehensive overview of steerable bone drill designs identified in patent literature via the Espacenet database and in scientific literature accessed via the Scopus data base. A Boolean search combined with pre-set inclusion criteria returned 78 literature references describing a variety of drill designs.

Results: These drill designs could be categorized based on how the drilling trajectory was defined. Three methods to influence the drilling trajectory were identified: (1) the device (57% of the sources), (2) the environment (15% of the sources): the path is defined based on the tissue interaction forces with the surrounding bone or (3) the user defines the drilling trajectory (28% of the sources).

Discussion: The comprehensive overview of steerable drilling methods provides insights in the possibilities in drill design and may be used as a source of inspiration for the design of novel steerable drill designs. ...
Positioning a thin needle into a solid substrate near a target region is difficult because the needle can easily bend and buckle. Nevertheless, in nature, female parasitic wasps can do this by using buckling prevention and steering mechanisms. This study presents a self-propelled needle that incorporates wasp-inspired steering mechanisms, specifically, the use of pretension and asymmetry within the needle segments. The needle with an outer diameter of 0.89 millimeters comprises seven parallel needle segments, with the central needle segment being either straight for a forward trajectory or prebent for steering purposes. By retracting and rotating the prebent central needle segment, the needle is capable of omnidirectional steering. The performance of the needle in tissue-mimicking phantoms was evaluated in terms of its propulsion efficiency and steering performance. The propulsion efficiency, affected by slippage of the needle segments with respect to the tissue-mimicking phantoms, was, on average, 63% ± 4% for forward motion and 55% ± 7% for steering motion. Moreover, the needle successfully steered with a mean deflection-to-insertion ratio of 0.41 ± 0.11 (i.e., radius-of-curvature of 44 mm). The proposed bioinspired needle design is a relevant step toward developing steerable needles for percutaneous interventions. ...
Journal article (2024) - J. Bloemberg, Zola Fung-A-Jou, P. Breedveld, A. Sakes
In percutaneous interventions, needles are used to reach target locations inside the body. However, when the needle is pushed through the tissue, forces arise at the needle tip and along the needle body, making the needle prone to buckling. Recently, needles that prevent buckling inspired by the ovipositor of female parasitic wasps have been developed. Building on these needle designs, this study proposes a manual actuation unit that allows the operator to drive the wasp-inspired needle through stationary tissue. The needle consists of six 0.3-mm spring steel wires, of which one is advanced while the others are retracted. The advancing needle segment has to overcome a cutting and friction force while the retracting ones experience a friction force in the opposite direction. The actuation unit moves the needle segments in the required sequence using a low-friction ball spline mechanism. The moving components of the needle have low inertia, and its connection to the actuation unit using a ball spline introduces a small friction force, generating a small push force on the needle that facilitates the needle’s propulsion into tissue while preventing needle buckling. Experimental testing evaluated the needle’s ability to move through stationary 15-wt% gelatin tissue phantoms for different actuation velocities. It was found that the needle moved through the tissue phantoms with mean slip ratios of 0.35, 0.31, and 0.29 for actuation velocities of π, 2π, and 3π rad/s, respectively. Furthermore, evaluation in 15-wt%, 10-wt%, and 5-wt% gelatin tissue phantoms showed that decreasing the gelatin concentration decreased the mean slip ratios from 0.35 to 0.19 and 0.18, respectively. The needle actuation system design is a step forward in developing a wasp-inspired needle for percutaneous procedures that prevents buckling. ...
Journal article (2024) - E.P. de Kater, D.J. Jager, P. Breedveld, A. Sakes
Pedicle screws have long been established as the gold standard for spinal bone fixation. However, their fixation strength can be compromised in cases of low bone density, particularly in osteoporotic bone, due to the reliance on a micro-shape lock between the screw thread and the surrounding bone. To address this challenge, we propose augmenting conventional pedicles screws with a curved compliant anchor. This anchor integrates a curved super-elastic nitinol rod that is advanced through a canulated pedicle screw, forming a macro-shape lock within the vertebral body to aid the fixation strength. Both placement safety and fixation strength of this novel spinal bone anchor were validated on tissue phantoms (Sawbones). The radius of the curved compliant anchor’s path demonstrates high precision while exhibiting strong dependence on the bone density in which the anchor is placed. When the curved compliant anchor is combined with a conventional pedicle screw, the mean maximum pull-out force elevated to 290 N, marking a 14% enhancement in pull-out resistance compared to using pedicle screw alone. Further augmentation with multiple curved compliant anchors holds promise for even greater fixation. The application of a curved compliant spinal bone anchor offers a promising means of increasing the fixation strength of pedicles screws, which is especially relevant in challenging clinical scenarios such a patient suffering from osteoporosis. ...
Metal additive manufacturing is a promising technology for the production of functional medical products, due to its high shape complexity and resolution, and ability to withstand sterilization temperatures. This study explores the possibility of designing a completely non-assembly steerable surgical instrument using Selective Laser Melting. Despite its advantages for medical devices, the rough surface quality of unfinished parts can be problematic for non-assembly designs, leading to increased friction and wear in rigid body mechanisms and tendon-actuated mechanisms. We investigated printing of rolling contact joints with crossed flexures as low-friction joints, adjusted for printing in titanium for the design of the instrument. Grid-based lattice structures were incorporated as miniature flexures, and we explored the influence of various grid sizes on the flexibility and bending stiffness of the lattices. Based on this exploration, we altered the rolling joint configuration from two crossed flexures to a single straight flexure for our design. The resulting steerable surgical instrument design is completely non-assembly, including its actuation, facilitates easy removal of support structures, and requires no surface finishing steps. It has a diameter of less than 20 mm, facilitates opening and closing of a grasper, and steering of the grasper by 20 degrees. ...
The success rate of spinal fusion surgery is mainly determined by the fixation strength of the spinal bone anchors. This study explores the use of an L-shaped spinal bone anchor that is intended to establish a macro-shape lock with the posterior cortical layer of the vertebral body, thereby increasing the pull-out resistance of the anchor. The performance of this L-shaped anchor was evaluated in lumbar vertebra phantoms (L1-L5) across four distinct perpendicular orientations (lateral, medial, superior, and inferior). During the pull-out experiments, the pull-out force, and the displacement of the anchor with respect to the vertebra was measured which allowed the determination of the maximal pull-out force (mean: 123 N ± 25 N) and the initial pull-out force, the initial force required to start motion of the anchor (mean: 23 N ± 16 N). Notably, the maximum pull-out force was observed when the anchor engaged the cortical bone layer. The results demonstrate the potential benefits of utilising a spinal bone anchor featuring a macro-shape lock with the cortical bone layer to increase the pull-out force. Combining the macro shape-lock fixation method with the conventional pedicle screw shows the potential to significantly enhance the fixation strength of spinal bone anchors. ...
Journal article (2024) - Fabian Trauzettel, Emmanuel Vander Poorten, Mouloud Ourak, Jenny Dankelman, Paul Breedveld
While articulated surgical instruments have enabled the proliferation of minimally invasive interventions, procedures such as laparo-endoscopic single-site surgery are waning in popularity. One potential reason for this decline is a lack of sufficiently dexterous instruments. Although multi-steerable instruments exist, these are often complex and therefore expensive assemblies. Even when 3D printing was used to simplify the design of these instruments, the requirement for high-performance 3D printers limited the reduction in manufacturing costs. To tackle this issue, we propose six guidelines for converting a 3D printed compliant medical instrument from printing on a Digital Light Processing (DLP) printer to a Fused Filament Fabrication (FFF) printer. These guidelines provide a framework to manage and compensate for differences in the two processes to achieve comparable results at a reduced cost. The proposed guidelines were evaluated by assembling a FFF 3D printed prototype that shows equivalent performance to its DLP 3D printed counterpart. ...
Pipelines, vital for fluid transport, pose an important yet challenging inspection task, particularly in small, flexible biological systems, that robots have yet to master. In this study, we explored the development of an innovative robot inspired by the ovipositor of parasitic wasps to navigate and inspect pipelines. The robot features a flexible locomotion system that adapts to different tube sizes and shapes through a mechanical inflation technique. The flexible locomotion system employs a reciprocating motion, in which groups of three sliders extend and retract in a cyclic fashion. In a proof-of-principle experiment, the robot locomotion efficiency demonstrated positive linear correlation (r = 0.6434) with the diameter ratio (ratio of robot diameter to tube diameter). The robot showcased a remarkable ability to traverse tubes of different sizes, shapes and payloads with an average of (70%) locomotion efficiency across all testing conditions, at varying diameter ratios (0.7 1.5). Furthermore, the mechanical inflation mechanism displayed substantial load-carrying capacity, producing considerable holding force of (13 N), equivalent to carrying a payload of (≈5.8 Kg) inclusive the robot weight. This soft robotic system shows promise for inspection and navigation within tubular confined spaces, particularly in scenarios requiring adaptability to different tube shapes, sizes, and load-carrying capacities. The design of this system serves as a foundation for a new class of pipeline inspection robots that exhibit versatility across various pipeline environments, potentially including biological systems. ...
Journal article (2024) - J. Bloemberg, B. Hoppener, Bram Coolen, A. Sakes, P. Breedveld
Transperineal laser ablation is a minimally invasive thermo-ablative treatment for prostate cancer that requires the insertion of a needle for accurate optical fiber positioning. Needle insertion in soft tissues may cause tissue motion and deformation, resulting in tissue damage and needle positioning errors. In this study, we present a wasp-inspired self-propelled needle that uses pneumatic actuation to move forward with zero external push force, thus avoiding large tissue motion and deformation. The needle consists of six parallel 0.25-mm diameter Nitinol rods driven by a pneumatic actuation system. The pneumatic actuation system consists of Magnetic Resonance (MR) safe 3D-printed parts and off-the-shelf plastic screws. A self-propelled motion is achieved by advancing the needle segments one by one, followed by retracting them simultaneously. The advancing needle segment has to overcome a cutting and friction force, while the stationary needle segments experience a friction force in the opposite direction. The needle self-propels through the tissue when the friction force of the five stationary needle segments overcomes the sum of the friction and cutting forces of the advancing needle segment. We evaluated the prototype’s performance in 10-wt% gelatin phantoms and ex vivo porcine liver tissue inside a preclinical Magnetic Resonance Imaging (MRI) scanner in terms of the slip ratio of the needle with respect to the phantom or liver tissue. Our results demonstrated that the needle was able to self-propel through the phantom and liver tissue with slip ratios of 0.912–0.955 and 0.88, respectively. The prototype is a promising step toward the development of self-propelled needles for MRI-guided transperineal laser ablation as a method to treat prostate cancer. ...

A systematic review on pubic arch interference and needle positioning errors

Review (2024) - Jette Bloemberg, Martijn de Vries, Luigi A.M.J.G. van Riel, Theo M. de Reijke, Aimée Sakes, Paul Breedveld, John J. van den Dobbelsteen
Introduction: This study focuses on the quantification of and current guidelines on the hazards related to needle positioning in prostate cancer treatment: (1) access restrictions to the prostate gland by the pubic arch, so-called Pubic Arch Interference (PAI) and (2) needle positioning errors. Next, we propose solution strategies to mitigate these hazards. Methods: The literature search was executed in the Embase, Medline ALL, Web of Science Core Collection*, and Cochrane Central Register of Controlled Trials databases. Results: The literature search resulted in 50 included articles. PAI was reported in patients with various prostate volumes. The level of reported PAI varied between 0 and 22.3 mm, depending on the patient’s position and the measuring method. Low-Dose-Rate Brachytherapy induced the largest reported misplacement errors, especially in the cranio-caudal direction (up to 10 mm) and the largest displacement errors were reported for High-Dose-Rate Brachytherapy in the cranio-caudal direction (up to 47 mm), generally increasing over time. Conclusions: Current clinical guidelines related to prostate volume, needle positioning accuracy, and maximum allowable PAI are ambiguous, and compliance in the clinical setting differs between institutions. Solutions, such as steerable needles, assist in mitigating the hazards and potentially allow the physician to proceed with the procedure. This systematic review was performed in accordance with the PRISMA guidelines. The review was registered at Protocols.io (DOI: dx.doi.org/10.17504/protocols.io.6qpvr89eplmk/v1). ...
Introduction: Bone biopsies have great value for the diagnosis of, amongst others, hematologic diseases. Although the bone biopsy procedure is mostly performed minimally invasive with the use of a slender cannula, the patient may still experience discomfort, especially when the procedure has to be repeated due to an unsuccessful biopsy. Areas covered: This review presents a comprehensive overview of bone biopsy devices presented in the patent literature. The patents were obtained using a classification search combined with keywords in the Espacenet patent database and were subsequently verified using pre-set eligibility criteria. This resulted in 62 unique patents included in this review. Expert opinion: The included patents were categorized based on the used strategies for the three steps that can be identified during a bone biopsy (1) biopsy sampling, (2) biopsy severing and (3) biopsy harvesting. Most patents described strategies for multiple steps. Insight into the used strategies and the comprehensive overview may serve as a source of inspiration for the design of novel bone biopsy devices. ...

Design of a Vitrectome Mechanism for Eye Surgery

Journal article (2023) - K.M. Lussenburg, Marta Scali, Maarten Stolk, D. Robijns, A. Sakes, P. Breedveld
A vitrectome is a commonly used instrument in eye surgery, which is used to cut and aspirate the vitreous body out of the eye. The mechanism of the vitrectome consists of miniature components that need to be assembled by hand due to their size. Non-assembly 3D printing, in which fully functional mechanisms can be produced in a single production step, can help create a more streamlined production process. We propose a vitrectome design based on a dual-diaphragm mechanism, which can be produced with minimal assembly steps using PolyJet printing. Two different diaphragm designs were tested to fulfill the requirements of the mechanism: a homogenous design based on ‘digital’ materials and a design using an ortho-planar spring. Both designs were able to fulfill the required displacement for the mechanism of 0.8 mm, as well as cutting forces of at least 8 N. The requirements for the cutting speed of the mechanism of 8000 RPM were not fulfilled by both designs, since the viscoelastic nature of the PolyJet materials resulted in a slow response time. The proposed mechanism does show promise to be used in vitrectomy; however, we suggest that more research into different design directions is required. ...

A Review on Scientific and Patent Literature

Conventional medical instruments are not capable of passing through tortuous anatomy as required for natural orifice transluminal endoscopic surgery due to their rigid shaft designs. Nevertheless, developments in minimally invasive surgery are pushing medical devices to become more dexterous. Amongst devices with controllable flexibility, so-called Follow-The-Leader (FTL) devices possess motion capabilities to pass through confined spaces without interacting with anatomical structures. The goal of this literature study is to provide a comprehensive overview of medical devices with FTL motion. A scientific and patent literature search was performed in five databases (Scopus, PubMed, Web of Science, IEEExplore, Espacenet). Keywords were used to isolate FTL behavior in devices with medical applications. Ultimately, 35 unique devices were reviewed and categorized. Devices were allocated according to their design strategies to obtain the three fundamental sub-functions of FTL motion: steering, (controlling the leader/end-effector orientation), propagation, (advancing the device along a specific path), and conservation (memorizing the shape of the path taken by the device). A comparative analysis of the devices was carried out, showing the commonly used design choices for each sub-function and the different combinations. The advantages and disadvantages of the design aspects and an overview of their performance were provided. Devices that were initially assessed as ineligible were considered in a possible medical context or presented with FTL potential, broadening the classification. This review could aid in the development of a new generation of FTL devices by providing a comprehensive overview of the current solutions and stimulating the search for new ones. ...
Conference paper (2023) - Mahdieh Shojaei Baghini, Kristiaan Broekens, Michiel Oderwald, Paul Breedveld, Hadi Heidari, Maurits Van Der Heiden
Magnetostrictive strain sensors with high spinorbit coupling have been integrated with Fiber-Bragg-Grating sensors wherein the gap within the gratings varies with strain within the encapsulating magnetostrictive material. Terfenol-D has been chosen as the mm sized magnetostrictive material which exhibits the largest known bulk magnetostriction. The setup utilised consists of an optical to electrical transducer leading to lower noise in the system while carrying out sensing in the magneto-optic domain. Non-linear isotropic analytical modeling and linear anisotropic finite element modeling is carried out to gain further insight into the variation of material parameters with external magnetic field intensity. The operated magnetic fields lie within 100 µT with a sensor sensitivity of 0.6 kHz/ppm, thus reducing risks due to any prolonged or repeated exposure. This technology can be integrated with state-of-the-art sensors with high sensitivity to create smaller and safer tracking systems, particularly in-vivo. ...