Integrated Continuous Biomanufacturing reduces manufacturing costs while maintaining product quality. A key contributor to high biopharmaceutical costs, specifically monoclonal antibodies (mAbs), is chromatography. Protein A ligands are usually preferred but still expensive in the manufacturing context, and batch chromatography under-utilizes the columns' capacity, compromising productivity to maintain high yields. Continuous chromatography increases columns' Capacity Utilization (CU) without sacrificing yield or productivity. This work presents the in-silico optimization of a 3 Column Periodic Counter-current Chromatography (3C-PCC) of a capture and polishing step for mAbs from a high titer harvest (cmAb = 5 g/L). The 3C-PCC was modeled and Pareto-fronts for continuous and batch modes were used to optimize the 3C-PCC steps varying the flow rate and percentage of breakthrough achieved in the interconnected loading, maximizing Productivity and CU, for varying concentrations of mAb (batch mode concentration of 5 g/L and continuous mode concentration of 2.5, 5, 7.5, and 10 g/L). The shape of the breakthrough curve significantly impacts the optimization of 3C-PCC. The model output was validated for three different protein A ligands using a pure mAb solution. MAb Select SuRe pcc was selected to continuously capture mAb from a high-titer clarified cell culture supernatant (harvest). The product eluates were pooled and used for continuous polishing using a Cation-Exchange resin (CaptoS ImpAct). Experimental results validated model predictions (<7% deviation in the worst case) and a process with two 3C-PCC in sequence was proposed, with a productivity of approximately 100 mg/mL res/h.
...
Integrated Continuous Biomanufacturing reduces manufacturing costs while maintaining product quality. A key contributor to high biopharmaceutical costs, specifically monoclonal antibodies (mAbs), is chromatography. Protein A ligands are usually preferred but still expensive in the manufacturing context, and batch chromatography under-utilizes the columns' capacity, compromising productivity to maintain high yields. Continuous chromatography increases columns' Capacity Utilization (CU) without sacrificing yield or productivity. This work presents the in-silico optimization of a 3 Column Periodic Counter-current Chromatography (3C-PCC) of a capture and polishing step for mAbs from a high titer harvest (cmAb = 5 g/L). The 3C-PCC was modeled and Pareto-fronts for continuous and batch modes were used to optimize the 3C-PCC steps varying the flow rate and percentage of breakthrough achieved in the interconnected loading, maximizing Productivity and CU, for varying concentrations of mAb (batch mode concentration of 5 g/L and continuous mode concentration of 2.5, 5, 7.5, and 10 g/L). The shape of the breakthrough curve significantly impacts the optimization of 3C-PCC. The model output was validated for three different protein A ligands using a pure mAb solution. MAb Select SuRe pcc was selected to continuously capture mAb from a high-titer clarified cell culture supernatant (harvest). The product eluates were pooled and used for continuous polishing using a Cation-Exchange resin (CaptoS ImpAct). Experimental results validated model predictions (<7% deviation in the worst case) and a process with two 3C-PCC in sequence was proposed, with a productivity of approximately 100 mg/mL res/h.
Journal article(2023)
-
Mariana N. São Pedro, Madelène Isaksson, Joaquín Gomis-Fons, Michel H.M. Eppink, Bernt Nilsson, Marcel Ottens
The implementation of continuous processing in the biopharmaceutical industry is hindered by the scarcity of process analytical technologies (PAT). To monitor and control a continuous process, PAT tools will be crucial to measure real-time product quality attributes such as protein aggregation. Miniaturizing these analytical techniques can increase measurement speed and enable faster decision-making. A fluorescent dye (FD)-based miniaturized sensor has previously been developed: a zigzag microchannel which mixes two streams under 30 s. Bis-ANS and CCVJ, two established FDs, were employed in this micromixer to detect aggregation of the biopharmaceutical monoclonal antibody (mAb). Both FDs were able to robustly detect aggregation levels starting at 2.5%. However, the real-time measurement provided by the microfluidic sensor still needs to be implemented and assessed in an integrated continuous downstream process. In this work, the micromixer is implemented in a lab-scale integrated system for the purification of mAbs, established in an ÄKTA™ unit. A viral inactivation and two polishing steps were reproduced, sending a sample of the product pool after each phase directly to the microfluidic sensor for aggregate detection. An additional UV sensor was connected after the micromixer and an increase in its signal would indicate that aggregates were present in the sample. The at-line miniaturized PAT tool provides a fast aggregation measurement, under 10 min, enabling better process understanding and control.
...
The implementation of continuous processing in the biopharmaceutical industry is hindered by the scarcity of process analytical technologies (PAT). To monitor and control a continuous process, PAT tools will be crucial to measure real-time product quality attributes such as protein aggregation. Miniaturizing these analytical techniques can increase measurement speed and enable faster decision-making. A fluorescent dye (FD)-based miniaturized sensor has previously been developed: a zigzag microchannel which mixes two streams under 30 s. Bis-ANS and CCVJ, two established FDs, were employed in this micromixer to detect aggregation of the biopharmaceutical monoclonal antibody (mAb). Both FDs were able to robustly detect aggregation levels starting at 2.5%. However, the real-time measurement provided by the microfluidic sensor still needs to be implemented and assessed in an integrated continuous downstream process. In this work, the micromixer is implemented in a lab-scale integrated system for the purification of mAbs, established in an ÄKTA™ unit. A viral inactivation and two polishing steps were reproduced, sending a sample of the product pool after each phase directly to the microfluidic sensor for aggregate detection. An additional UV sensor was connected after the micromixer and an increase in its signal would indicate that aggregates were present in the sample. The at-line miniaturized PAT tool provides a fast aggregation measurement, under 10 min, enabling better process understanding and control.