U. Weber
Please Note
2 records found
1
HollandPTC is an independent outpatient center for proton therapy, scientific research, and education. Patients with different types of cancer are treated with Intensity Modulated Proton Therapy (IMPT). Additionally, the HollandPTC R&D consortium conducts scientific research into the added value and improvements of proton therapy. To this end, HollandPTC created clinical and pre-clinical research facilities including a versatile R&D proton beamline for various types of biologically and technologically oriented research. In this work, we present the characterization of the R&D proton beamline of HollandPTC. Its pencil beam mimics the one used for clinical IMPT, with energy ranging from 70 up to 240 MeV, which has been characterized in terms of shape, size, and intensity. For experiments that need a uniform field in depth and lateral directions, a dual ring passive scattering system has been designed, built, and characterized. With this system, field sizes between 2 × 2 cm2 and 20 × 20 cm2 with 98 % uniformity are produced with dose rates ranging from 0.5 Gy/min up to 9 Gy/min. The unique and customized support of the dual ring system allows switching between a pencil beam and a large field in a very simple and fast way, making the HollandPTC R&D proton beam able to support a wide range of different applications.
The roadmap for space exploration foresees longer journeys and further excursions outside low-Earth orbit as well as the establishment of permanent outposts on other celestial bodies, such as the Moon or Mars. The design of spacecrafts and habitats depends heavily on the mission scenario and must consider the radiation protection properties of the structural components as well as dedicated shielding. In fact, short- and long-term effects caused by exposure to cosmic radiation are now considered among the main health risks of space travel. One of the current strategies is to find multifunctional materials that combine excellent mechanical properties with a high shielding effectiveness to minimize the overall load. In this work, the shielding effectiveness of a wide variety of single and multilayer materials of interest for different mission scenarios has been characterized. In the experimental campaign, reference and innovative materials, as well as simulants of Moon and Mars in situ resources, were irradiated with 1,000 MeV/u 4He, 430 MeV/u 12C and 962-972 MeV/u 56Fe. The results are presented in terms of Bragg curves and dose reduction per unit area density. To isolate the shielding effectiveness only due to nuclear fragmentation, a correction for the energy loss in the material is also considered. These findings indicate that the best shield is lithium hydride, which performs even better than polyethylene. However, the technical feasibility of shielding needs to be investigated. The classification of all materials in terms of shielding effectiveness is not influenced by the ion species, but the value changes dramatically depending on the beam energy. The output of this investigation represents a useful database for benchmarking Monte Carlo and deterministic transport codes used for space radiation transport calculations. These findings also contribute to recommendations for optimizing the design of space vessels and habitats in different radiation environments.