We review the status of a 1.4 GW, 8 GWh underground pumped hydro storage (U-PHS) project in the southern Netherlands, which has been under development since the 1980s. Its history shows how the prospect of a large-scale U-PHS for The Netherlands (a country whose proverbial flatness prohibits PHS) has been attractive in every decade, based on proven technology in a subsurface location with validated properties, and solid analysis of its economics. Although the ongoing energy transition clearly requires massive electricity storage, (U-)PHS projects are challenging investment propositions, in The Netherlands, as elsewhere. This case study illustrates a point of general relevance, namely that although the project execution risk, related to uncertainty with respect to subsurface integrity, is very low, the transition risk, associated with the intrinsic uncertainties of an electricity system in transition, is significant. We point out mitigation strategies for both risk categories.
The effect of pressure-dependent changes in vascular volume, resistance and capacitance in the coronary micro-circulation, has been studied by a distributed mathematical model of the coronary micro-vasculature in the left ventricular wall. The model does not include regulation of coronary blood flow and is evaluated only for the fully dilated coronary vasculature. The left ventricular wall was thought to consist of eight parallel layers, each of them with an arteriolar, capillary and venular compartment. The resistance of each vessel was thought to depend on the inverse of squared volume, according to Poiseuille's Law for tubes with constant length. Tissue pressure has been assumed to be equal to left ventricular cavity pressure at the endocardium and to decrease linearly to atmospheric level at the epicardium. The pressure-volume relation of the vessel compartments were assumed to be sigmoidal. There is a rest volume at transmural pressure zero and ΔV/ΔP decreases with increasing transmural pressure. Simulation of experimental protocols described by other authors yielded results which were similar to the experimental outcomes, illustrated by: (1) a parallel shift to the flow axis of the pressure-flow curves due to cardiac arrest (2) steady-state endo/epi ratio of flow as a function of heart rate. It is concluded that interpretation of transients in coronary flow and/or pressure by models containing fixed resistance and capacitance may seriously underestimate intramyocardial capacitative effects and characteristic time constants for pressure-induced resistance changes.