Electron microscopy (EM) allows ultrastructural analysis of biological tissues and cells, but images frequently contain artifacts because biological samples have to undergo rigorous preparation to be resistant to vacuum conditions and electron beam exposure. Knowledge about the appearance of image artifacts and how they arise is crucial for their recognition and mitigation and for proper image interpretation. How artifacts appear depends strongly on the electron detection modality and the imaging conditions. Optical scanning transmission EM (OSTEM) is a detection technique compatible with single-beam and multibeam electron microscopes, in which tissue samples are directly deposited on a scintillator for imaging in transmission mode. Here, we identified several types of artifacts that may occur in single-beam and multibeam OSTEM. These artifacts arise or appear as a result of combining established sample preparation protocols with solid scintillator substrates and optical transmission detection. Artifacts can be effectively mitigated or minimized to ultimately enable high quality large-scale 2D and 3D acquisitions.
FAST-EM array tomography:
A workflow for multibeam volume electron microscopy
Recent advances in electron microscopy techniques have led to a significant scale up in volumetric imaging of biological tissue. The throughput of electron microscopes, however, remains a limiting factor for the volume that can be imaged in high resolution within reasonable time. Faster detection methods will improve throughput. Here, we have characterized and benchmarked a novel detection technique for scanning electron microscopy: optical scanning transmission electron microscopy (OSTEM). A qualitative and quantitative comparison was performed between OSTEM, secondary and backscattered electron detection and annular dark field detection in scanning transmission electron microscopy. Our analysis shows that OSTEM produces images similar to backscattered electron detection in terms of contrast, resolution and signal-to-noise ratio. OSTEM can complement large scale imaging with (scanning) transmission electron microscopy and has the potential to speed up imaging in single-beam scanning electron microscope.
Detailed knowledge of biological structure has been key in understanding biology at several levels of organisation, from organs to cells and proteins. Volume electron microscopy (volume EM) provides high resolution 3D structural information about tissues on the nanometre scale. However, the throughput rate of conventional electron microscopes has limited the volume size and number of samples that can be imaged. Recent improvements in methodology are currently driving a revolution in volume EM, making possible the structural imaging of whole organs and small organisms. In turn, these recent developments in image acquisition have created or stressed bottlenecks in other parts of the pipeline, like sample preparation, image analysis and data management. While the progress in image analysis is stunning due to the advent of automatic segmentation and server-based annotation tools, several challenges remain. Here we discuss recent trends in volume EM, emerging methods for increasing throughput and implications for sample preparation, image analysis and data management.
Volume electron microscopy (EM) of biological systems has grown exponentially in recent years due to innovative large-scale imaging approaches. As a standalone imaging method, however, large-scale EM typically has two major limitations: slow rates of acquisition and the difficulty to provide targeted biological information. We developed a 3D image acquisition and reconstruction pipeline that overcomes both of these limitations by using a widefield fluorescence microscope integrated inside of a scanning electron microscope. The workflow consists of acquiring large field of view fluorescence microscopy (FM) images, which guide to regions of interest for successive EM (integrated correlative light and electron microscopy). High precision EM-FM overlay is achieved using cathodoluminescent markers. We conduct a proof-of-concept of our integrated workflow on immunolabelled serial sections of tissues. Acquisitions are limited to regions containing biological targets, expediting total acquisition times and reducing the burden of excess data by tens or hundreds of GBs.
Integrated Array Tomography
Development and Applications of a Workflow for 3D Correlative Light and Electron Microscopy
Large-scale electron microscopy (EM) allows analysis of both tissues and macromolecules in a semi-automated manner, but acquisition rate forms a bottleneck. We reasoned that a negative bias potential may be used to enhance signal collection, allowing shorter dwell times and thus increasing imaging speed. Negative bias potential has previously been used to tune penetration depth in block-face imaging. However, optimization of negative bias potential for application in thin section imaging will be needed prior to routine use and application in large-scale EM. Here, we present negative bias potential optimized through a combination of simulations and empirical measurements. We find that the use of a negative bias potential generally results in improvement of image quality and signal-to-noise ratio (SNR). The extent of these improvements depends on the presence and strength of a magnetic immersion field. Maintaining other imaging conditions and aiming for the same image quality and SNR, the use of a negative stage bias can allow for a 20-fold decrease in dwell time, thus reducing the time for a week long acquisition to less than 8 h. We further show that negative bias potential can be applied in an integrated correlative light electron microscopy (CLEM) application, allowing fast acquisition of a high precision overlaid LM-EM dataset. Application of negative stage bias potential will thus help to solve the current bottleneck of image acquisition of large fields of view at high resolution in large-scale microscopy.
The authors present the application of a retarding field between the electron objective lens and sample in an integrated fluorescence and electron microscope. The retarding field enhances signal collection and signal strength in the electron microscope. This is beneficial for samples prepared for integrated fluorescence and electron microscopy as the amount of staining material added to enhance electron microscopy signal is typically lower compared to conventional samples in order to preserve fluorescence. We demonstrate signal enhancement through the applied retarding field for both 80-nm post-embedding immunolabeled sections and 100-nm in-resin preserved fluorescence sections. Moreover, we show that tuning the electron landing energy particularly improves imaging conditions for ultra-thin (50 nm) sections, where optimization of both retarding field and interaction volume contribute to the signal improvement. Finally, we show that our integrated retarding field setup allows landing energies down to a few electron volts with 0.3 eV dispersion, which opens new prospects for assessing electron beam induced damage by in situ quantification of the observed bleaching of the fluorescence following irradiation.