Muhammad Danang Birowosuto
Please Note
3 records found
1
Current trends in material research for nuclear batteries
Harnessing metal perovskite halides and other chalcogenides for greater compactness and efficiency
(BZA)2PbBr4
A potential scintillator for photon-counting computed tomography detectors
Due to recent development in detector technology, photon-counting computed tomography (PCCT) has become a rapidly emerging medical imaging technology. Current PCCT systems rely on the direct conversion of X-ray photons into charge pulses, using CdTe, CZT, or Si semiconductor detectors. Indirect detection using ultrafast scintillators coupled to silicon photomultipliers (SiPM) offers a potentially more straightforward and cost-effective alternative. In this work a new 2D perovskite scintillator, benzylamonium lead bromide (BZA)2PbBr4, is experimentally characterised as function of temperature. The material exhibits a 4.2 ns decay time under X-ray excitation at room temperature and a light yield of 3700 photons/MeV. The simulation tool developed by Van der Sar et al. was used to model the pulse trains produced by a SiPM-based (BZA)2PbBr4 detector. The fast decay time of (BZA)2PbBr4 results in outstanding count-rate performance as well as very low statistical fluctuations in the simulated pulses. These features of (BZA)2PbBr4, combined with its cost-effective synthesis make (BZA)2PbBr4 very promising for PCCT.
In this work the scintillation properties of PEA2PbBr4 are studied as function of temperature, accessing the potential use of these materials for low temperature applications. The scintillation properties and mechanism have been studied using a combination of temperature dependent photoluminescence emission and excitation, X-ray excited emission and decay measurements. At room temperature the X-ray excited emission is dominated by the 442 nm emission with a lifetime of 35.2 ns. Under UV-Vis photon excitation an additional emission peak is observed at 412 nm. At 10 K, both X-ray and UV-Vis photon excited emission spectra show a narrow emission peak at 412 nm and a broad emission band centred around 525 nm with a lifetime of 1.53 ns (24%) and 154 ns (76%) respectively. The exact nature of the observed emission peaks is not known. For this reason two potential mechanisms explaining the difference between UV-Vis photon and X-ray excitation and their temperature dependent emissions are explored. The total spectral intensity decreases to 72% of the intensity at room temperature at 10 K. It is suggested that the observed negative thermal quenching behaviour results from a combination of more self absorption and a higher degree of self trapped exciton formation under X-ray excitation. Based on the observed fast decay component at 10 K and light yield of 9400 photons per MeV at room temperature, showing only a 28% decrease at 10 K, could make this material potentially interesting for low temperature and fast timing applications.