Christophe J.P. Smeets
Please Note
3 records found
1
Background: Cardiac rehabilitation (CR) is known for its beneficial effects on functional capacity and is a key component within current cardiovascular disease management strategies. In addition, a larger increase in functional capacity is accompanied by better clinical outcomes. However, not all patients respond in a similar way to CR. Therefore, a patient-tailored approach to CR could open up the possibility to achieve an optimal increase in functional capacity in every patient. Before treatment can be optimized, the differences in response of patients in terms of cardiac adaptation to exercise should first be understood. In addition, digital biomarkers to steer CR need to be identified. Objective: The aim of the study was to investigate the difference in cardiac response between patients characterized by a clear improvement in functional capacity and patients showing only a minor improvement following CR therapy. Methods: A total of 129 patients in CR performed a 6-minute walking test (6MWT) at baseline and during four consecutive short-term follow-up tests while being equipped with a wearable electrocardiogram (ECG) device. The 6MWTs were used to evaluate functional capacity. Patients were divided into high- and low-response groups, based on the improvement in functional capacity during the CR program. Commonly used heart rate parameters and cardiac digital biomarkers representative of the heart rate behavior during the 6MWT and their evolution over time were investigated. Results: All participating patients improved in functional capacity throughout the CR program (P<.001). The heart rate parameters, which are commonly used in practice, evolved differently for both groups throughout CR. The peak heart rate (HR peak) from patients in the high-response group increased significantly throughout CR, while no change was observed in the low-response group (F 4,92=8.321, P<.001). Similar results were obtained for the recovery heart rate (HR rec) values, which increased significantly over time during every minute of recuperation, for the high-response group (HR rec1: P<.001, HR rec2: P<.001, HR rec3: P<.001, HR rec4: P<.001, and HR rec5: P=.02). The other digital biomarkers showed that the evolution of heart rate behavior during a standardized activity test differed throughout CR between both groups. These digital biomarkers, derived from the continuous measurements, contribute to more in-depth insight into the progression of patients' cardiac responses. Conclusions: This study showed that when using wearable sensor technology, the differences in response of patients to CR can be characterized by means of commonly used heart rate parameters and digital biomarkers that are representative of cardiac response to exercise. These digital biomarkers, derived by innovative analysis techniques, allow for more in-depth insights into the cardiac response of cardiac patients during standardized activity. These results open up the possibility to optimized and more patient-tailored treatment strategies and to potentially improve CR outcome.
Short-term exercise progression of cardiovascular patients throughout cardiac rehabilitation
An observational study
Cardiac rehabilitation (CR) is a highly recommended secondary prevention measure for patients with diagnosed cardiovascular disease. Unfortunately, participation rates are low due to enrollment and adherence issues. As such, new CR delivery strategies are of interest, as to improve overall CR delivery. The goal of the study was to obtain a better understanding of the short-term progression of functional capacity throughout multidisciplinary CR, measured as the change in walking distance between baseline six-minute walking test (6MWT) and four consecutive follow-up tests. One-hundred-and-twenty-nine patients diagnosed with cardiovascular disease participated in the study, of which 89 patients who completed the whole study protocol were included in the statistical analysis. A one-way repeated measures ANOVA was conducted to determine whether there was a significant change in mean 6MWT distance (6MWD) throughout CR. A three-way-mixed ANOVA was performed to determine the influence of categorical variables on the progression in 6MWD between groups. Significant differences in mean 6MWD between consecutive measurements were observed. Two subgroups were identified based on the change in distance between baseline and end-of-study. Patients who increased most showed a linear progression. In the other group progression leveled off halfway through rehabilitation. Moreover, the improvement during the initial phase of CR seemed to be indicative for overall progression. The current study adds to the understanding of the short-term progression in exercise capacity of patients diagnosed with cardiovascular disease throughout a CR program. The results are not only of interest for CR in general, but could be particularly relevant in the setting of home-based CR.
Cardiovascular diseases (CVD) are often characterized by their multifactorial complexity. This makes remote monitoring and ambulatory cardiac rehabilitation (CR) therapy challenging. Current wearable multimodal devices enable remote monitoring. Machine learning (ML) and artificial intelligence (AI) can help in tackling multifaceted datasets. However, for clinical acceptance, easy interpretability of the AI models is crucial. The goal of the present study was to investigate whether a multi-parameter sensor could be used during a standardized activity test to interpret functional capacity in the longitudinal follow-up of CR patients. A total of 129 patients were followed for 3 months during CR using 6-min walking tests (6MWT) equipped with a wearable ECG and accelerometer device. Functional capacity was assessed based on 6MWT distance (6MWD). Linear and nonlinear interpretable models were explored to predict 6MWD. The t-distributed stochastic neighboring embedding (t-SNE) technique was exploited to embed and visualize high dimensional data. The performance of support vector machine (SVM) models, combining different features and using different kernel types, to predict functional capacity was evaluated. The SVM model, using chronotropic response and effort as input features, showed a mean absolute error of 42.8 m (±36.8 m). The 3D-maps derived using the t-SNE technique visualized the relationship between sensor-derived biomarkers and functional capacity, which enables tracking of the evolution of patients throughout the CR program. The current study showed that wearable monitoring combined with interpretable ML can objectively track clinical progression in a CR population. These results pave the road towards ambulatory CR.