PV

Peter Veenstra

info

Please Note

3 records found

Journal article (2025) - Ankur Kislaya, Aniket Ashwin Samant, Peter Veenstra, Daniel S.W. Tam, Jerry Westerweel
This paper presents a microfluidic approach that dynamically controls the hydrodynamic flow and the streamlines to enable complex multi-particle manipulations within a single device. The approach combines the design of a flow-through microfluidic Hele-Shaw flow cell together with an optimization procedure to find a priori optimal particle pathlines, and an effective proportional-integral-derivative (PID) feedback controller to provide real-time control over the particle manipulations. In the device, particles are manipulated with hydrodynamic forces, by using a uniform flow through the flow cell and three inlets perpendicular to the flow cell. The streamlines within the device are manipulated by injecting or extracting fluid through the three inlets. The Hele-Shaw geometry allows a fast and accurate prediction of the particle trajectory, meaning only a simple PID controller is required to correct for particle deviations. The robustness of this approach is demonstrated by implementing multiple functions within the device, including particle trapping, particle sorting, particle separation, and assembly. The real-time control procedure affords accurate particle manipulation, with a maximum error on the order of the diameter of the particle. ...

A novel framework to study unsteady microfluidic flows

Journal article (2020) - Ankur Kislaya, Antaran Deka, Peter Veenstra, Daniel S.W. Tam, Jerry Westerweel
Abstract: In microscopic particle image velocimetry (micro-PIV), correlation averaging over multiple frames is often required, leading to a loss in temporal resolution, therefore limiting the measurement accuracy for unsteady flows. Here, we present a new PIV method suitable to study steady and unsteady laminar flows between parallel plates (i.e., Hele-Shaw flow), which is a common flow configuration in microfluidic applications. Our method reduces the effective seeding density and yields similar if not higher signal-to-noise ratio (SNR) compared to conventional micro-PIV. We call this algorithm Ψ -PIV. Ψ -PIV requires a much smaller number of frames to reach the same SNR compared to the widely used correlation averaging method. This leads to a significant improvement of the temporal resolution. The Ψ -PIV algorithm is used in an experimental investigation of steady and unsteady flows in a Hele-Shaw cell. Our experiment shows that Ψ -PIV reduces the number of required frames by 8 times and 30 times compared to the frames required by conventional PIV for steady and unsteady laminar flow, respectively. In this study, PIV and Ψ -PIV use a single-pass cross-correlation to present the underlying difference between the two approaches. Graphic abstract: [Figure not available: see fulltext.]. ...
Conference paper (2018) - Ankur Kislaya, Antaran Deka, Peter Veenstra, Daniel Tam, Jerry Westerweel
In micro-PIV, reaching the optimum image density has always been difficult due to high displacement gradient, coagulation of particles at the inlet and due to particles adhering to the surface to name a few. The most widely used method is to take ensemble correlation average of multiple PIV images to extract the velocity field. However, this leads to low temporal resolution. Hence, a method with high temporal resolution is pivotal to study unsteady laminar flow in microfluidic application. This work aims at developing a new PIV algorithm which reduces the effective seeding density and at the same time yield similar if not higher SNR compared to conventional PIV. We call this algorithm Ψ-PIV. This method is suitable for steady and unsteady laminar flows which are generally found in microfluidic applications. The reliability and the precision of the new method as a function of particle image pairs is investigated by synthetic image analysis. The main advantage of Ψ-PIV is its ability to achieve higher temporal resolution from the typical micro-PIV raw images. The experimental investigation for the flow around a 2D cylinder in a Hele-Shaw cell showed that the Ψ-PIV results in a reduction by approximately a factor of 25 in the number of frames required compared to conventional PIV. ...