HS

Hugo Simões

info

Please Note

2 records found

Journal article (2024) - D. R. Guerreiro, J. G. Saraiva, L. Peralta, C. Rodrigues, M. Rovituso, E. van der Wal, Dennis R. Schaart, P. Crespo, H. Simões, J. M. Sampaio
Objective. Bragg peak measurements play a key role in the beam quality assurance in proton therapy. Used as base data for the treatment planning softwares, the accuracy of the data is crucial when defining the range of the protons in the patient. Approach. In this paper a protocol to reconstruct a Pristine Bragg Peak exploring the direct correlation between the particle flux and the dose deposited by particles is presented. Proton flux measurements at the HollandPTC and FLUKA Monte Carlo simulations are used for this purpose. This new protocol is applicable to plastic scintillator detectors developed for Quality Assurance applications. In order to obtain the Bragg curve using a plastic fiber detector, a PMMA phantom with a decoupled and moveable stepper was designed. The step phantom allows to change the depth of material in front of the fiber detector during irradiations. The Pristine Bragg Peak reconstruction protocol uses the measured flux of particles at each position and multiplies it by the average dose obtained from the Monte Carlo simulation at each position. Main results. The results show that with this protocol it is possible to reconstruct the Bragg Peak with an accuracy of about 470 µm, which is in accordance with the tolerances set by the AAPM. Significance. It has the advantage to be able to overcome the quenching problem of scintillators in the high ionization density region of the Bragg peak. ...
Journal article (2018) - Patricia Cambraia Lopes, Paulo Crespo, Hugo Simões, Rui Ferreira Marques, Katia Parodi, Dennis R. Schaart
Prompt-gamma (PG) imaging has the potential for monitoring proton therapy in real time. Different approaches are investigated. We focus on developing multi-slat collimators to image PG quanta, aiming at optimizing collimator performance to detect deviations in treatment delivery. We investigated six different multi-slat configurations, which have either optimal (analytical) intrinsic spatial resolution at fixed efficiency, or otherwise; at different distances from the proton pencil-beam axis (15 cm–35 cm). We used Geant4 to simulate irradiations of the head (energy: 130 MeV) and pelvis (200 MeV) of an anthropomorphic phantom, with and without physiologic/morphologic or setup changes of clinical dosimetric relevance. The particles escaping the phantom were transported through each of these multi-slat configurations and the gamma counts profiles were recorded at the collimator exit. Median filtering was applied to the registered PG-profiles to mitigate the effects of septa shadowing and statistical fluctuations. Time-of-flight discrimination was used to enhance the signal-to-background ratio, which appeared crucial for 200 MeV irradiations. Visual detection of the artificially introduced changes was possible by comparing the PG to the depth-dose profiles. Moreover, 2 mm range shifts could be detected in the head irradiation case using a simple linear regression fit to the falloff of the PG-profile. The influence of changes in complex, patient-like dose distributions on the PG-profiles obtained with multi-slat collimation is first studied in this work, which further gives insight on collimator design optimization and highlights its potential and simplicity for detecting proton treatment deviations over a wide range of Bragg peak positions. ...