XH

Xinlei Hu

Authored

2 records found

This paper presents a research on the chloride penetration behavior of engineered cementitious composites (ECC) under sustained flexural loads. Three load levels, i.e. 30 %, 60 % and 75 % of the ultimate flexural load were used. Chloride diffusion depth and concentration profile ...
The resistance of cracked ECC against chloride ingress is mainly governed by the accumulated crack width of all the cracks rather than the maximum width of multiple cracks. However, most studies focus on the influence of a single fine crack@en