Jd

Jan-Willem A. den Herder

info

Please Note

2 records found

Conference paper (2026) - Martin de Wit, K. Nagayoshi, L Gottardi, E. Taralli, Sven Visser, K. Ravensberg, J.R. Gao, Jan-Willem A. den Herder
We report on the development and cryogenic tests of a full-sized array of Transition Edge Sensors (TESs) designed for the X-ray Integral Field Unit (X-IFU). The wafer, comprising a fully-wired array of over 1500 high-performance TES microcalorimeters, was fabricated to meet the stringent requirements of the X-IFU. The quality of the full-sized array is assessed by the study of representative smaller arrays on pop-out diagnostic chips located near the mean array on the same wafer. Characterization is performed using a dedicated DC-biased setup featuring PTB SQUIDs and SRON lithographically-defined shunt resistors and Nyquist inductors. This setup enables the characterization of up to 14 detectors in a single cooling run. Comprehensive measurements at milliKelvin temperatures were conducted to evaluate the detector uniformity, transition parameters, noise characteristics, and energy resolution. Our results demonstrate excellent uniformity over all devices tested on the different diagnostic chips. These findings demonstrate the robustness of the SRON TES technology, and raise confidence in our capability of delivering a full-fledged detector array that fulfils all requirements for X-IFU if the need arises. Our results also demonstrate the readiness of the detector technology for other laboratory applications or future X-ray observatories. ...
Journal article (2024) - Davide Vaccaro, Jan Van Der Kuur, Paul Van Der Hulst, Martin De Wit, Kevin Ravensberg, J. A. Chervenak, Joseph Adams, Jan-Willem A. den Herder, Jian Rong Gao, More Authors...
The X-ray Integral Field Unit (X-IFU) is an instrument of European Space Agency's future NewAthena space observatory, with the goal to provide high-energy resolution (<4 eV at X-ray energies up to 7 keV) and high-spatial resolution (9 in.) spectroscopic imaging over the X-ray energy range from 200 eV to 12 keV, by means of an array of ∼1500 transition-edge sensors (TESs) read out via superconducting quantum interference device time-division multiplexing (TDM). A TDM-based laboratory test bed has been assembled at Netherlands Institute for Space Research, hosting an array of 75×75 μm2 TESs that are read out via 2-column × 32-row TDM. A system component that is critical to high-performance operation is the wiring harness that connects the room-temperature electronics to the cryogenic readout componentry. We report here on our characterization of such a test bed, whose harness has a length close to what was envisioned for X-IFU, which allowed us to achieve a co-added energy resolution at a level of 2.7-eV full width half maximum at 6 keV via 32-row readout. In addition, we provide an outlook on the integration of TDM readout into the X-IFU focal plane assembly development model. ...