Journal article (2023) - Nick Marsidi, Karlijn M.J. Scheepens, Jelle J. Goeman, Tim Horeman, Roel E. Genders
Mechanical stress influences scarring of a surgical wound. Several lines have been proposed for the best excision direction. It is unknown if these lines still apply when the body posture changes. The objective is to measure the skin reaction force in four directions and determine the direction of least force. Secondary objective is to determine if the reaction force varies in a different body posture. Skin reaction force was measured with the compressiometer in 30 participants on four different locations (forearm/upper arm/shoulder blade/lower back) in four directions (0°–45°–90°–135°) and two body postures. The direction of least skin reaction force changed with a different body posture and was significant for the forearm (p < 0.01) and shoulder blade (p = 0.05) The skin reaction force in all four direction changed significantly in a different body posture, except the 45° line in the upper arm and shoulder blade. Our results demonstrate that the skin reaction force in four directions in four locations varies with change in body posture. Focus should therefore not only lay on choosing the right direction, but also on managing skin tension postoperatively. ...

Towards a new skin tensiometer for research and surgical planning

Journal article (2021) - Karlijn M.J. Scheepens, Nick Marsidi, Roel E. Genders, Tim Horeman-Franse
After surgery, around 35% of patients experience problems of excessive scarring, causing disfiguring and impaired function. An incision placed in the wrong direction causes unnecessary skin tension on the wound, resulting in increased collagen disposition and potentially hypertrophic scars. Currently, skin tension lines are used for incision planning. However, these lines are not universal and are a static representation of the skin tension that is in fact under influence of muscle action. By designing a new skin force measurement device the authors intend to make research on dynamic skin characteristics possible and to objectify incision planning and excision closure planning. The device applies a known compressive force to the skin in standardized directions and measures the displacement of the skin. This allows users to measure the skin reaction force in response to compression and to determine the optimal incision line or best wound closure direction. The device has an accuracy of 96% and a sensitivity of < 0.01 mm. It is compact, works non-invasively and standardizes measurement directions and is therefore an improvement over previously designed skin tensiometers. ...
Journal article (2020) - Nick Marsidi, Sofieke A.M. Vermeulen, Tim Horeman, Roel E. Genders
Background: The use of sutures remains the first choice for wound closure. However, incorrect use of a suture technique can lead to impaired healing. Many techniques are described for high-tension wounds, but not much is known about their mechanical properties. Complications of excessive tension include dehiscence, infection, and ischemic necrosis and could be prevented. This study aimed to compare forces in five techniques (single, horizontal mattress, vertical mattress, pulley, and modified pulley suture) in a standardized wound tension model. Materials and methods: A standardized neoprene wound model was developed on the ForceTRAP system (MediShield B.V., Delft, The Netherlands) to mimic a 5 Newton (N) wound. Five different suture techniques were each repeated 10 times by a student, resident dermatology, and dermsurgeon. The pulling force of the suture's first throw was measured with the Hook-in-Force sensor (Technical University Delft, The Netherlands). Changes in wound tension were measured by the ForceTRAP system. The ForceTRAP is a platform measuring forces from 0 to 20 N in three dimensions with an accuracy of 0.1 N. The Hook-in-Force is a force sensor measuring 0-15 N with an accuracy of 0.5 N. Maximum and mean forces were calculated for each suture technique and operator. Results: Mean maximum pulling force: 5.69 N (standard deviation [SD], 0.88) single, 7.25 N (SD, 1.33) vertical mattress, 8.11 N (SD, 1.00) horizontal mattress, 3.46 N (SD, 0.61) pulley, and 4.52 N (SD, 0.67) modified pulley suture. The mean force increase on the skin (substitute) ranged between 0.80 N (pulley) and 0.96 N (vertical mattress). Conclusions: The pulley suture requires less pulling force compared with other techniques. The mechanical properties of sutures should be taken in consideration when choosing a technique to close wounds. ...