SG

Said A. Goueli

info

Please Note

4 records found

Journal article (2021) - Almotasembellah Abushaban, Sergio G. Salinas-Rodriguez, Delia Pastorelli, Jan C. Schippers, Subhanjan Mondal, Said Goueli, Maria D. Kennedy
In this study, the removal of particulate, organic and biological fouling potential was investigated in the two-stage dual media filtration (DMF) pretreatment of a full-scale seawater reverse osmosis (SWRO) desalination plant. Moreover, the removal of fouling potential in two-stage DMF (DMF pretreatment) was compared with the removal in two-stage DMF installed after dissolved air floatation (DAF) (DAF-DMF pretreatment). For this purpose, the silt density index (SDI), modified fouling index (MFI), bacterial growth potential (BGP), organic fractions and microbial adenosine triphosphate (ATP) were monitored in the pretreatment processes of two full-scale SWRO plants. Particulate fouling potential was well controlled through the two stages of DMF with significant removal of SDI15 (>80%), MFI0.45 (94%) and microbial ATP (>95%). However, lower removal of biological/organic fouling potential (24–41%) was observed due to frequent chlorination (weekly) of the pretreatment, resulting in low biological activity in the DMFs. Therefore, neutralizing chlorine before media filtration is advised, rather than after, as is the current practice in many full-scale SWRO plants. Comparing overall removal in the DAF-DMF pretreatment to that of the DMF pretreatment showed that DAF improved the removal of biological/organic fouling potential, in which the removal of BGP and biopolymers increased by 40% and 16%, respectively. Overall, monitoring ATP and BGP during the pretreatment processes, particularly in DMF, would be beneficial to enhance biological degradation and lower biofouling potential in SWRO feed water. ...
Journal article (2020) - A.M.J. Abushaban, Sergio G. Salinas-Rodriguez, Moses Kapala, Delia Pastorelli, Jan C. Schippers, Subhanjan Mondal, Said Goueli, Maria D. Kennedy
Several potential growth methods have been developed to monitor biological/organic fouling potential in seawater reverse osmosis (SWRO), but to date the correlation between these methods and biofouling of SWRO has not been demonstrated. In this research, the relation between a new adenosine triphosphate (ATP)-based bacterial growth potential (BGP) test of SWRO feed water and SWRO membrane performance is investigated. For this purpose, the pre-treatment of a full-scale SWRO plant including dissolved air flotation (DAF) and two stage dual media filtration (DMF) was monitored for 5 months using BGP, orthophosphate, organic fractions by liquid chromatography coupled with organic carbon detection (LC-OCD), silt density index (SDI), and modified fouling index (MFI). Results showed that particulate fouling potential was well controlled through the SWRO pre-treatment as the measured SDI and MFI in the SWRO feed water were below the recommended values. DAF in combination with coagulation (1–5 mg-Fe3+/L) consistently achieved 70% removal of orthophosphate, 50% removal of BGP, 25% removal of biopolymers, and 10% removal of humic substances. Higher BGP (100–950 µg-C/L) in the SWRO feed water corresponded to a higher normalized pressure drop in the SWRO, suggesting the applicability of using BGP as a biofouling indicator in SWRO systems. However, to validate this conclusion, more SWRO plants with different pre-treatment systems need to be monitored for longer periods of time. ...

Eliminating seawater matrix effects using a filtration-based method

Journal article (2019) - Almotasembellah Abushaban, Sergio G. Salinas-Rodriguez, Muhammad Nasir Mangal, Subhanjan Mondal, Said A. Goueli, Aleksandra Knezev, Johannes S. Vrouwenvelder, Jan C. Schippers, Maria D. Kennedy
A direct method for measuring adenosine-triphosphate (ATP) in seawater was developed recently, in which commercial reagents are added directly to seawater. However, calibration is required if seawater quality changes (such as changes in salinity, pH, Mg2+, Fe3+) as the seawater matrix interferes with ATP measurement. In this research, a 0.1 μm filtration process is introduced to eliminate such interferences. In addition, a filter rinsing step with sterilized artificial seawater is proposed to eliminate interference of free ATP. The ATP-filtration method is fast (<5 min), reproducible (VC = 7%), six times more sensitive than the direct ATP-method and correlates (R2 = 0.72, n = 100) with intact cell concentration. Microbial ATP concentration measured using the ATP-filtration method and the ATP-direct method were comparable. Microbial ATP measured along the treatment train of a full-scale seawater reverse osmosis (SWRO) plant decreased from 530 in the raw seawater to 10 ng-ATP/L after pre-treatment and to 0.5 ng-ATP/L in the SWRO permeate. The method was also applied to monitor bacterial growth potential (BGP) across the pre-treatment train of a (pilot) seawater desalination plant, where the removal of BGP through the media filtration and ultrafiltration was 44% and 7%, respectively. ...
Journal article (2017) - Almotasembellah Abushaban, M. Nasir Mangal, Sergio G. Salinas-Rodriguez, Chidiebere Nnebuo, Subhanjan Mondal, Said A. Goueli, Jan C. Schippers, Maria D. Kennedy
The use of adenosine triphosphate (ATP) to monitor bacterial growth potential of seawater is currently not possible as ATP cannot be accurately measured at low concentration in seawater using commercially available luciferase-based ATP detection. The limitation is due to interference of salt with the luciferin–luciferase reaction, which inhibits light production. This research demonstrates that new reagents developed for (i) ATP extraction from microbial cells and (ii) ATP detection in seawater are able to reliably detect Microbial ATP as low as 0.3 ng L–1 in seawater. The luminescence signal of the new detection reagent is significantly higher (>20 times) than the luminescence signal of the freshwater reagent, when applied in seawater. ATP can now be used to monitor bacterial growth potential (BGP) through pre-treatment trains of seawater reverse osmosis (SWRO) plants. The level of detection of the new BGP test is significantly lower than the estimated threshold value required to prevent biofouling in SWRO systems. The new reagents have been used to monitor Microbial ATP in coastal North Sea water. Moreover, Microbial ATP has been applied to monitor the bacterial growth potential (using indigenous bacteria) through the pre-treatment train of an SWRO desalination plant. A significant reduction (>55%) of the bacterial growth potential was found through the dual media filtration with 4.5 mg-Fe(III) L–1 coagulant. Overall, the new reagents can detect low Microbial ATP concentrations in seawater and can be used to monitor bacterial growth potential in seawater desalination plants. ...