KJ

Konstantins Jefimovs

info

Please Note

6 records found

Journal article (2015) - Stephan R. Fagerer, Andreas Römpp, Konstantins Jefimovs, Rolf Brönnimann, Gerd Hayenga, Robert F. Steinhoff, Jasmin Krismer, Martin Pabst, Alfredo J. Ibáñez, Renato Zenobi
Rationale Up to now, there is no 'gold standard' for determining the resolution of a mass spectrometry imaging (MSI) setup (comprising the instrument, the sample preparation, the sample and the instrument settings). A standard sample in combination with a standard protocol to define the MSI resolution would be desirable in order to compare the setups of different laboratories, and as a regular quality control/performance check. Methods Microstructured resolution patterns were fabricated that can be used to determine the spatial resolution in MSI experiments, down to the range of a few μm. Two different strategies were employed, one where the resolution pattern is laser machined into a thin metal foil, which can be placed over a sample to be imaged, and a second one where hydrophilic grooves are machined into an omniphobic coating covering the surface of an indium tin oxide covered glass slide. When dragging a sample solution over the slide's surface, the sample is automatically retained in the hydrophilic grooves, but repelled by the omniphobic coating. Results The technology was tested on a commercial matrix-assisted laser desorption/ionization (MALDI) imaging instrument, and a spatial resolution in the vicinity of 50 μm was determined. The finest features of the microstructured resolution patterns are compatible with the best spatial resolution of MALDI imaging systems available to date. Conclusions The use of metal resolution grids or glass slides with hydrophilic/hydrophobic structures is suitable for the convenient determination of the resolution limit of the MALDI imaging instrument as determined by its hardware. These structures are straightforward both to produce and to use. ...
Journal article (2014) - Martin Pabst, Stephan Rupert Fagerer, Rudolf Köhling, Klaus Eyer, Jasmin Krismer, Konstantins Jefimovs, Alfredo Jesus Ibáñez, Renato Zenobi
Drug monitoring is usually performed by liquid chromatography coupled with optical detection or electrospray ionization mass spectrometry. More recently, matrix-assisted laser desorption/ionization (MALDI) in combination with triple quadrupole or Fourier-transform (FT) mass analyzers has also been reported to allow accurate quantification. Here, we present a strategy that employs standard MALDI time-of-flight (TOF) mass spectrometry (MS) for the sensitive and accurate quantification of saquinavir from an extract of blood peripheral mononuclear cells. Unambiguous identification of saquinavir in the mass spectra was possible because of using internal mass calibration and by an overall low chemical noise in the low mass range. Exact mass determination of the constant background peaks of the cell extract, which were used for recalibration, was performed by an initial MALDI-FT-MS analysis. Fast and multiplexed sample analysis was enabled by microarray technology, which provided 10 replicates in the lower nL range for each sample in parallel lanes on a chip. In order to validate the method, we employed various statistical tests, such as confidence intervals for linear regressions, three quality control samples, and inverse confidence limits of the estimated concentration ratios. [Figure not available: see fulltext.] ...
Journal article (2014) - A. Mareike Schmidt, Stephan R. Fagerer, Konstantins Jefimovs, Florian Buettner, Christian Marro, Erdem C. Siringil, Karl L. Boehlen, Martin Pabst, Alfredo J. Ibáñez
Studying cell-to-cell heterogeneity requires techniques which robustly deliver reproducible results with single-cell sensitivity. Through a new fabrication method for the microarrays for mass spectrometry (MAMS) platform, we now have attained robustness and reproducibility in our single-cell level mass spectrometry measurements that allowed us to combine single-cell MAMS-based measurements from different days and samples. By combining multiple measurements, we were able to identify three co-existing phenotypes in an isogenic population of Saccharomyces cerevisiae characterized by distinctively different levels of glycolytic intermediates. ...
Journal article (2014) - Simon K. Küster, Martin Pabst, Konstantins Jefimovs, Renato Zenobi, Petra S. Dittrich
We present a robust droplet-based device, which enables the fractionation of ultralow flow rate nanoflow liquid chromatography (nano-LC) eluate streams at high frequencies and high peak resolution. This is achieved by directly interfacing the separation column to a micro T-junction, where the eluate stream is compartmentalized into picoliter droplets. This immediate compartmentalization prevents peak dispersion during eluate transport and conserves the chromatographic performance. Subsequently, nanoliter eluate fractions are collected at a rate of one fraction per second on a high-density microarray to retain the separation with high temporal resolution. Chromatographic separations of up to 45 min runtime can thus be archived on a single microarray possessing 2700 sample spots. The performance of this device is demonstrated by fractionating the separation of a tryptic digest of a known protein mixture onto the microarray chip and subsequently analyzing the sample archive using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Resulting peak widths are found to be significantly reduced compared to standard continuous flow spotting technologies as well as in comparison to a conventional nano-LC-electrospray ionization-mass spectrometry interface. Moreover, we demonstrate the advantage of our high-definition nanofractionation device by applying two different MALDI matrices to all collected fractions in an alternating fashion. Since the information that is obtained from a MALDI-MS measurement depends on the choice of MALDI matrix, we can extract complementary information from neighboring spots containing almost identical composition but different matrices. ...
Journal article (2013) - Stephan R. Fagerer, Thomas Schmid, Alfredo J. Ibáñez, Martin Pabst, Robert Steinhoff, Konstantins Jefimovs, Pawel L. Urban, Renato Zenobi
In order to investigate metabolic properties of single cells of freshwater algae (Haematococcus pluvialis), we implement matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) in combination with microspectroscopic mapping. Straightforward coupling of these two detection platforms was possible thanks to the self-aliquoting properties of micro-arrays for mass spectrometry (MAMS). Following Raman and fluorescence imaging, the isolated cells were covered with a MALDI matrix for targeted metabolic analysis by MALDI-MS. The three consecutive measurements carried out on the same cells yielded complementary information. Using this method, we were able to study the encystment of H. pluvialis-by monitoring the adenosine triphosphate (ATP) to adenosine diphosphate (ADP) ratio during the build-up of astaxanthin in the cells as well as the release of β-carotene, the precursor of astaxanthin, into the cytosol. ...
Journal article (2013) - Martin Pabst, Stephan R. Fagerer, Rudolf Köhling, Simon K. Küster, Robert Steinhoff, Martin Badertscher, Fabian Wahl, Petra S. Dittrich, Konstantins Jefimovs, Renato Zenobi
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a fast analysis tool employed for the detection of a broad range of analytes. However, MALDI-MS has a reputation of not being suitable for quantitative analysis. Inhomogeneous analyte/matrix co-crystallization, spot-to-spot inhomogeneity, as well as a typically low number of replicates are the main contributing factors. Here, we present a novel MALDI sample target for quantitative MALDI-MS applications, which addresses the limitations mentioned above. The platform is based on the recently developed microarray for mass spectrometry (MAMS) technology and contains parallel lanes of hydrophilic reservoirs. Samples are not pipetted manually but deposited by dragging one or several sample droplets with a metal sliding device along these lanes. Sample is rapidly and automatically aliquoted into the sample spots due to the interplay of hydrophilic/hydrophobic interactions. With a few microliters of sample, it is possible to aliquot up to 40 replicates within seconds, each aliquot containing just 10 nL. The analyte droplet dries immediately and homogeneously, and consumption of the whole spot during MALDI-MS analysis is typically accomplished within few seconds. We evaluated these sample targets with respect to their suitability for use with different samples and matrices. Furthermore, we tested their application for generating calibration curves of standard peptides with α-cyano-4-hdydroxycinnamic acid as a matrix. For angiotensin II and [Glu1]-fibrinopeptide B we achieved coefficients of determination (r2) greater than 0.99 without the use of internal standards. ...