TA

Tibor Agócs

info

Please Note

20 records found

Journal article (2020) - Brunella Carlomagno, Christian Delacroix, Olivier Absil, Faustine Cantalloube, Gilles Orban de Xivry, Prashant Pathak, Tibor Agocs, Bernhard Brandl, Matthew Kenworthy
With the advent of 30- to 40-m class ground-based telescopes in the mid-2020s, direct imaging of exoplanets is bound to take a new major leap. Among the approved projects, the Mid-infrared Extremely Large Telescope (ELT) Imager and Spectrograph (METIS) instrument for the ELT holds a prominent spot; by observing in the mid-infrared regime, it will be perfectly suited to study a variety of exoplanets and protoplanetary disks around nearby stars. Equipped with two of the most advanced coronagraphs, the vortex coronagraph and the apodizing phase plate, METIS will provide high-contrast imaging (HCI) in L-, M- and N-bands, and a combination of high-resolution spectroscopy and HCI in L- and M-bands. We present the expected HCI performance of the METIS instrument, considering realistic adaptive optics residuals, and investigate the effect of the main instrumental errors. The most important sources of degradation are identified and realistic sensitivity limits in terms of planet/star contrast are derived. ...
Conference paper (2020) - Tibor Agocs, Eddy Elswijk, Daan Zaalberg, Jan Rinze Peterzon, Niels Tromp, Ivan Lloro, Jeffrey Lynn, Ramon Navarro, Bernhard Brandl, More Authors...
We present the manufacturing and optical verification of the germanium immersed grating for the L/M band high resolution spectrograph (LMS). The LMS is one of the science subsystems of the Mid-infrared ELT Imager and Spectrograph, METIS. The immersed grating has very demanding requirement specifications: <100 nm RMS transmitted Wave Front Error (WFE) after double pass, and >70% peak throughput in all orders within the 2.9-5.3 μm wavelength range over the pupil. The grating has a period of 18.2 μm, a sawtooth groove profile with 89.6 degrees apex angle and a grating area of 150mm x 60mm. The germanium immersed grating was produced by Canon's high precision mechanical cutting technology. We present the interferometric tests that were performed in order to verify WFE and two different measurements (based on cascade laser and Fourier Transform Spectrometer, respectively) for throughput verification. ...

METIS high-contrast imaging: Design and expected performance (J. Astron. Telesc. Instrum. Syst. (2020) 6: 3 (035005) DOI: 10.1117/1.JATIS.6.3.035005)

Journal article (2020) - Brunella Carlomagno, Christian Delacroix, Olivier Absil, Faustine Cantalloube, Gilles Orban de Xivry, Prashant Pathak, Tibor Agocs, Bernhard Brandl, Matthew Kenworthy, More authors...
This article [J. Astron. Telesc. Instrum. Syst. 6(3), 035005 (Sep 24, 2020) DOI: 10.1117/1.JATIS.6.3.035005] as originally published omitted three authors as well as three references. The omitted authors produced the Apodizing Phase Plate design used in the paper’s end-to-end simulations. This contribution was provided by David Doelman, Emiel Por, and Frans Snik, all of Leiden University. They have been added as authors on the paper, as listed above. The following acknowledgment also has been added to the published paper: “The research of DD and FS leading to these results has received funding from the European Research Council under ERC Starting Grant agreement 678194 (FALCONER).” Additionally, three references were omitted from the paper when it was published. They are listed below: 61. G. Otten et al., “Performance characterization of a broadband vector Apodizing Phase Plate coronagraph,” Opt. Express 22(24), 30287 (2014). 62. G. Otten et al., “The vector apodizing phase plate coronagraph: prototyping, characterization and outlook,” Proc. SPIE 9151, 91511R (2014). 63. E. Por, “Optimal design of apodizing phase plate coronagraphs,” Proc. SPIE 10400, 104000V (2017). All versions of the article were corrected on 15 October 2020. The article appears correctly in print. ...
Conference paper (2020) - Leonard Burtscher, Ioannis Politopoulos, Sergio Fernández-Acosta, Tibor Agocs, Mario van den Ancker, Roy van Boekel, Bernhard Brandl, Hans-Ulrich Käufl, Eric Pantin, More authors...
Ground-based thermal-infrared observations have a unique scientific potential, but are also extremely challenging due to the need to accurately subtract the high thermal background. Since the established techniques of chopping and nodding need to be modified for observations with the future mid-infrared ELT imager and spectrograph (METIS), we investigate the sources of thermal background subtraction residuals. Our aim is to either remove or at least minimise the need for nodding in order to increase the observing efficiency for METIS. To this end we need to improve our knowledge about the origin of chop residuals and devise observing methods to remove them most efficiently, i.e. with the slowest possible nodding frequency. Thanks to dedicated observations with VLT/VISIR and GranTeCan/CanariCam, we have successfully traced the origin of three kinds of chopping residuals to (1) the entrance window, (2) the spiders and (3) other warm emitters in the pupil, in particular the VLT M3 mirror cell in its parking position. We conclude that, in order to keep chopping residuals stable over a long time (and therefore allow for slower nodding cycles), the pupil illumination needs to be kept constant, i.e. (imaging) observations should be performed in pupil-stabilised, rather than field-stabilised mode, with image de-rotation in the post-processing pipeline. This is now foreseen as the default observing concept for all METIS imaging modes. ...
Conference paper (2018) - Bernhard R. Brandl, Olivier Absil, Tibor Agócs, Felix Bettonvil, Leonard Burtscher, Ewine Van Dishoeck, Dirk Lesman, More Authors...
The Mid-Infrared ELT Imager and Spectrograph (METIS) is one of three first light instruments on the ELT. It will provide high-contrast imaging and medium resolution, slit-spectroscopy from 3 - 19um, as well as high resolution (R ∼ 100,000) integral field spectroscopy from 2.9-5.3μm. All modes observe at the diffraction limit of the ELT, by means of adaptive optics, yielding angular resolutions of a few tens of milliarcseconds. The range of METIS science is broad, from Solar System objects to active galactic nuclei (AGN). We will present an update on the main science drivers for METIS: circum-stellar disks and exoplanets. The METIS project is now in full steam, approaching its preliminary design review (PDR) in 2018. In this paper we will present the current status of its optical, mechanical and thermal design as well as operational aspects. We will also discuss the challenges of building an instrument for the ELT, and the required technologies. ...
Conference paper (2018) - Matthew A. Kenworthy, Olivier Absil, Brunella Carlomagno, Tibor Agócs, Emiel H. Por, Steven Bos, Bernhard Brandl, Frans Snik
The Mid-infrared E-ELT Imager and Spectrograph (METIS) for the European Extremely Large Telescope (E- ELT) consists of diffraction-limited imagers that cover 3 to 14 microns with medium resolution (R 5000) long slit spectroscopy, and an integral field spectrograph for high spectral resolution spectroscopy (R 100,000) over the L and M bands. We present our approach for high contrast imaging with METIS, covering diffraction suppression with coronagraphs, the removal of residual aberrations using QACITS1, 2 and Phase Sorting Interferometry (PSI),3 and simulations demonstrating the expected contrast. ...
Conference paper (2018) - Nicola Baccichet, Lucas Labadie, Adrian Glauser, Bernhard Brandl, Felix Bettonvil, Jeff Lynn, Andreas Eckart, Steffen Rost, Christian Straubmeier, Michael Wiest, Leonard Burtscher, Tibor Agócs, Willem Jellema, Ronald Roelfsema, Roy van Boekel
We present the preliminary design of the calibration unit of the future E-ELT instrument METIS. This independent subunit is mounted externally to the main cryostat of METIS and will function both as calibration reference for science observations, as well as verification and alignment tool during the AIT phase. In this paper, we focus on describing its preliminary layout and foreseen functionalities, based on the performance requirements defined at system level and the constraints imposed by warm IR background. We discuss the advantage of employing an integrating sphere as common radiation emitter, leading to a novel and versatile design, where the source's spatio-spectral properties can be varied with high fidelity and repeatability. By combining only few tuneable sources and mechanisms we show how a large instrument such as METIS can be calibrated and tested, without the need of a complex cold calibration unit. ...
Conference paper (2018) - Christian Straubmeier, Nicola Baccichet, Felix Bettonvil, Lucas Labadie, Steffen Rost, Michael Wiest, Andreas Eckart, Bernhard Brandl, Tibor Agócs, Ronald Roelfsema, Jeffrey Lynn
METIS, a mid-infrared imager and spectrograph for the wavelength range 2.9-19μm (astronomical L-, M-, N- and Q-band), will be one of the first three science instruments at the European Extremely Large Telescope (E-ELT). It will provide diffraction limited imaging, coronagraphy, high resolution integral field spectroscopy and low and medium resolution slit spectroscopy. Within the international METIS consortium, the 1st Institute of Physics of the University of Cologne in Germany is responsible for the design, manufacturing, integration and qualification of the Warm Calibration Unit (WCU) of the instrument. The WCU will be a self-contained unit operating at ambient temperature outside of the voluminous METIS dewar, feeding a variety of optical calibration and alignment signals into the optical path of METIS. The functionalities of the WCU will be used for routine daily daytime calibrations after astronomical observing nights and verification of the internal alignment of METIS during assembly, integration and verification (AIV). In this contribution we present the preliminary optical design and principle of operation of the WCU in its current state of the preliminary design phase of METIS. ...
Conference paper (2017) - R. Navarro, Tibor Agócs, L Venema, A.H. van Amerongen, M. Rodenhuis, Ruud W. M. Hoogeveen, T Coppens, Bernhard Brandl, R. Vink

Immersed gratings offer several advantages over conventional gratings: more compact spectrograph designs, and by using standard semiconductor industry techniques, higher diffraction-efficiency and lower stray-light can be achieved. We present the optical tests of the silicon immersed grating demonstrator for the Mid-infrared E-ELT Imager and Spectrograph, METIS. We detail the interferometric tests that were done to measure the wavefront-error and present the results of the throughput and stray-light measurements. We also elaborate on the challenges encountered and lessons learned during the immersed grating demonstrator test campaign that helped us to improve the fabrication processes of the grating patterning on the wafer.



...
Conference paper (2016) - Bernhard R. Brandl, Tibor Agócs, Manuel Güdel, Norma Hurtado, Rieks Jager, Matthew A. Kenworthy, Michael Mach, Jeff Meisner, Michael Meyer, Eric Pantin, Sascha Quanz, Hans Martin Schmid, Gabby Aitink-Kroes, Remko Stuik, Auke Veninga, Christoffel Waelkens, Thomas Bertram, Felix Bettonvil, Roy Van Boekel, Olivier Boulade, Markus Feldt, Alistair Glasse, Adrian Glauser
METIS is one the first three instruments on the E-ELT. Apart from diffraction limited imaging, METIS will provide coronagraphy and medium resolution slit spectroscopy over the 3 - 19μm range, as well as high resolution (R ∼ 100,000) integral field spectroscopy from 2.9 - 5.3μm, including a mode with extended instantaneous wavelength coverage. The unique combination of these observing capabilities, makes METIS the ideal instrument for the study of circumstellar disks and exoplanets, among many other science areas. In this paper we provide an update of the relevant science drivers, the METIS observing modes, the status of the simulator and the data analysis. We discuss the preliminary design of the optical system, which is driven by the need to calibrate observations at thermal IR wavelengths on a six-mirror ELT. We present the expected adaptive optics performance and the measures taken to enable high contrast imaging. We describe the opto-mechanical system, the location of METIS on the Nasmyth instrument platform, and conclude with an update on critical subsystem components, such as the immersed grating and the focal plane detectors. In summary, the work on METIS has taken off well and is on track for first light in 2025. ...