Development and Piezoelectric Properties of a Stack Units-Based Piezoelectric Device for Roadway Application

Journal Article (2021)
Authors

Chenchen Li (Tongji University, RWTH Aachen University)

Fan Yang (Tongji University)

Pengfei Liu (RWTH Aachen University)

Chaoliang Fu (RWTH Aachen University)

Quan Liu (RWTH Aachen University)

Hongduo Zhao (Tongji University)

P. Lin (TU Delft - Pavement Engineering)

Research Group
Pavement Engineering
Copyright
© 2021 Chenchen Li, Fan Yang, Pengfei Liu, Chaoliang Fu, Quan Liu, Hongduo Zhao, P. Lin
To reference this document use:
https://doi.org/10.3390/s21227708
More Info
expand_more
Publication Year
2021
Language
English
Copyright
© 2021 Chenchen Li, Fan Yang, Pengfei Liu, Chaoliang Fu, Quan Liu, Hongduo Zhao, P. Lin
Research Group
Pavement Engineering
Issue number
22
Volume number
21
Pages (from-to)
1-14
DOI:
https://doi.org/10.3390/s21227708
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

To improve the energy harvesting efficiency of the piezoelectric device, a stack units-based structure was developed and verified. Factors such as stress distribution, load resistance, loads, and loading times influencing the piezoelectric properties were investigated using theoretical analysis and experimental tests. The results show that the unit number has a negative relationship with the generated energy and the stress distribution has no influence on the power generation of the piezoelectric unit array. However, with a small stress difference, units in a parallel connection can obtain high energy conversion efficiency. Additionally, loaded with the matched impedance of 275.0 kΩ at 10.0 kN and 10.0 Hz, the proposed device reached a maximum output power of 84.3 mW, which is enough to supply the low-power sensors. Moreover, the indoor load test illustrates that the electrical performance of the piezoelectric device was positively correlated with the simulated loads when loaded with matched resistance. Furthermore, the electrical property remained stable after the fatigue test of 100,000 cyclic loads. Subsequently, the field study confirmed that the developed piezoelectric device had novel piezoelectric properties with an open-circuit voltage of 190 V under an actual tire load, and the traffic parameters can be extracted from the voltage waveform