On the Importance of Tracking the Negative-Sequence Phase-Angle in Three-Phase Inverters with Double Synchronous Reference Frame Current Control

Conference Paper (2020)
Author(s)

Lucia Beloqui Larumbe (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Zian Qin (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Pavol Bauer (TU Delft - Electrical Engineering, Mathematics and Computer Science)

Research Group
DC systems, Energy conversion & Storage
DOI related publication
https://doi.org/10.1109/ISIE45063.2020.9152442 Final published version
More Info
expand_more
Publication Year
2020
Language
English
Research Group
DC systems, Energy conversion & Storage
Article number
9152442
Pages (from-to)
1284-1289
ISBN (print)
978-1-7281-5636-1
ISBN (electronic)
978-1-7281-5635-4
Event
29th IEEE International Symposium on Industrial Electronics (2020-06-17 - 2020-06-19), Delft, Netherlands
Downloads counter
223
Collections
Institutional Repository
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

A voltage imbalance at the AC terminals of a three-phase inverter creates a ripple in the power signal on the DC side. In order to minimize this ripple, several techniques can be applied, in which a double Synchronous Reference Frame (SRF) current control structure is very typical. In this approach, both the positive and negative sequence currents are controlled. This technique has been shown to have an adequate response against imbalances; however, this paper shows that in the typical implementation of the double SRF control, the output AC pq instantaneous powers will have a constant error due to the phase-angle misalignment of the negative sequence with the positive sequence. Based on mathematical formulations and simulation results, this paper shows that this AC-power error exists, and that it is due to the above reason. In order to overcome this, this paper proposes to have a phase-tracking system that specifically follows the negative sequence phase-angle. The results show that this implementation is able to properly control the output AC power.