The Amsterdam Foot Model

a clinically informed multi-segment foot model developed to minimize measurement errors in foot kinematics

Journal Article (2022)
Author(s)

Wouter Schallig (Universiteit van Amsterdam, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences)

J. C. van den Noort (Amsterdam Movement Sciences, Universiteit van Amsterdam)

Marjolein Piening (Vrije Universiteit Amsterdam)

Geert J. Streekstra (Amsterdam Movement Sciences, Universiteit van Amsterdam)

Mario Maas (Amsterdam Movement Sciences, Universiteit van Amsterdam)

Marjolein Margaretha van der Krogt (Vrije Universiteit Amsterdam, Amsterdam Movement Sciences)

Jaap Harlaar (Vrije Universiteit Amsterdam, Erasmus MC, TU Delft - Biomechatronics & Human-Machine Control)

Research Group
Biomechatronics & Human-Machine Control
Copyright
© 2022 Wouter Schallig, Josien C. van den Noort, Marjolein Piening, Geert J. Streekstra, Mario Maas, Marjolein M. van der Krogt, J. Harlaar
DOI related publication
https://doi.org/10.1186/s13047-022-00543-6
More Info
expand_more
Publication Year
2022
Language
English
Copyright
© 2022 Wouter Schallig, Josien C. van den Noort, Marjolein Piening, Geert J. Streekstra, Mario Maas, Marjolein M. van der Krogt, J. Harlaar
Research Group
Biomechatronics & Human-Machine Control
Issue number
1
Volume number
15
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Background: Foot and ankle joint kinematics are measured during clinical gait analyses with marker-based multi-segment foot models. To improve on existing models, measurement errors due to soft tissue artifacts (STAs) and marker misplacements should be reduced. Therefore, the aim of this study is to define a clinically informed, universally applicable multi-segment foot model, which is developed to minimize these measurement errors. Methods: The Amsterdam foot model (AFM) is a follow-up of existing multi-segment foot models. It was developed by consulting a clinical expert panel and optimizing marker locations and segment definitions to minimize measurement errors. Evaluation of the model was performed in three steps. First, kinematic errors due to STAs were evaluated and compared to two frequently used foot models, i.e. the Oxford and Rizzoli foot models (OFM, RFM). Previously collected computed tomography data was used of 15 asymptomatic feet with markers attached, to determine the joint angles with and without STAs taken into account. Second, the sensitivity to marker misplacements was determined for AFM and compared to OFM and RFM using static standing trials of 19 asymptomatic subjects in which each marker was virtually replaced in multiple directions. Third, a preliminary inter- and intra-tester repeatability analysis was performed by acquiring 3D gait analysis data of 15 healthy subjects, who were equipped by two testers for two sessions. Repeatability of all kinematic parameters was assessed through analysis of the standard deviation (σ) and standard error of measurement (SEM). Results: The AFM was defined and all calculation methods were provided. Errors in joint angles due to STAs were in general similar or smaller in AFM (≤2.9°) compared to OFM (≤4.0°) and RFM (≤6.7°). AFM was also more robust to marker misplacement than OFM and RFM, as a large sensitivity of kinematic parameters to marker misplacement (i.e. > 1.0°/mm) was found only two times for AFM as opposed to six times for OFM and five times for RFM. The average intra-tester repeatability of AFM angles was σ:2.2[0.9°], SEM:3.3 ± 0.9° and the inter-tester repeatability was σ:3.1[2.1°], SEM:5.2 ± 2.3°. Conclusions: Measurement errors of AFM are smaller compared to two widely-used multi-segment foot models. This qualifies AFM as a follow-up to existing foot models, which should be evaluated further in a range of clinical application areas.