Comparison of 2D, 3D In Vitro, and Ex Vivo Platforms for Modeling the Rat Small Intestine

Journal Article (2026)
Author(s)

Shani Elias-Kirma (University of Cambridge)

Reece McCoy (University of Cambridge)

Douglas van Niekerk (University of Cambridge)

Verena Stoeger (University of Cambridge)

Sophie Oldroyd (University of Cambridge)

Emma Sumner (University of Cambridge)

Achilleas Savva (University of Cambridge, TU Delft - Bio-Electronics)

Róisín M. Owens (University of Cambridge)

DOI related publication
https://doi.org/10.3390/bioengineering13030349 Final published version
More Info
expand_more
Publication Year
2026
Language
English
Journal title
Bioengineering
Issue number
3
Volume number
13
Article number
349
Downloads counter
12
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Physiologically relevant in vitro intestinal models are essential for studying key physiological processes, including barrier function, drug screening and gut-microbiota interactions. However, conventional 2D culture systems often fail to recapitulate structural and functional complexity. Here, we aimed to validate a 3D bioelectronic transmembrane platform, previously used for monitoring human intestinal epithelium and vascular endothelium, for modeling the rat small intestinal barrier in vitro. The device integrates a poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) scaffold supporting co-cultures of rat intestinal epithelial cells (IEC-6) and rat fibroblasts (208F), enabling real-time monitoring of barrier formation through electrical measurements using electrochemical impedance spectroscopy (EIS). Barrier formation was monitored over 21 days and exhibited a time-dependent increase in barrier resistance. The 3D platform was compared with traditional 2D insert-based cultures and ex vivo rat tissue using an Ethylene Glycol Tetraacetic Acid (EGTA)-induced calcium switch assay to evaluate barrier disruption and recovery. EGTA treatment and removal induced reversible barrier disruption in the 3D in vitro and ex vivo models, whereas 2D in vitro cultures showed limited recovery. These findings demonstrate that the 3D platform more faithfully recapitulates native tissue architecture and function, closely paralleling ex vivo responses. Our study highlights the importance of validating advanced 3D in vitro models and establishes this bioelectronic platform as a robust tool for drug screening, barrier studies, and preclinical gastrointestinal research.