Maximizing Thermal Energy Recovery from Drinking Water for Cooling Purpose

Journal Article (2021)
Author(s)

Jawairia Imtiaz Ahmad (TU Delft - Sanitary Engineering, National University of Science and Technology (NUST))

Sara Giorgi (Waternet)

L. Zlatanović (Amsterdam Institute for Advanced Metropolitan Solutions (AMS), TU Delft - Sanitary Engineering, PWN Waterleidingbedrijf Noord-Holland)

G Liu (TU Delft - Sanitary Engineering, Chinese Academy of Sciences)

J.P. van der Hoek (TU Delft - Sanitary Engineering, PWN Waterleidingbedrijf Noord-Holland, Waternet)

Research Group
Sanitary Engineering
Copyright
© 2021 J.I. Ahmad, Sara Giorgi, L. Zlatanovic, G. Liu, J.P. van der Hoek
DOI related publication
https://doi.org/10.3390/en14092413
More Info
expand_more
Publication Year
2021
Language
English
Copyright
© 2021 J.I. Ahmad, Sara Giorgi, L. Zlatanovic, G. Liu, J.P. van der Hoek
Research Group
Sanitary Engineering
Issue number
9
Volume number
14
Pages (from-to)
1-14
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Drinking water distribution networks (DWDNs) have a huge potential for cold thermal energy recovery (TED). TED can provide cooling for buildings and spaces with high cooling requirements as an alternative for traditional cooling, reduce usage of electricity or fossil fuel, and thus TED helps reduce greenhouse gas (GHG) emissions. There is no research on the environmental assessment of TED systems, and no standards are available for the maximum temperature limit (Tmax) after recovery of cold. During cold recovery, the water temperature increases, and water at the customer’s tap may be warmer as a result. Previous research showed that increasing Tmax up to 30 °C is safe in terms of microbiological risks. The present research was carried out to determine what raising Tmax would entail in terms of energy savings, GHG emission reduction and water temperature dynamics during transport. For this purpose, a full-scale TED system in Amsterdam was used as a benchmark, where Tmax is currently set at 15 °C. Tmax was theoretically set at 20, 25 and 30 °C to calculate energy savings and CO2 emission reduction and for water temperature modeling during transport after cold recovery. Results showed that by raising Tmax from the current 15 °C to 20, 25 and 30 °C, the retrievable cooling energy and GHG emission reduction could be increased by 250, 425 and 600%, respectively. The drinking water temperature model predicted that within a distance of 4 km after TED, water temperature resembles that of the surrounding subsurface soil. Hence, a higher Tmax will substantially increase the TED potential of DWDN while keeping the same comfort level at the customer’s tap.