Zero energy potential of a high-rise office building in a Mediterranean climate

Using multi-objective optimization to understand the impact of design decisions towards zero-energy high-rise buildings

Journal Article (2020)
Author(s)

Evangelia Despoina Giouri (Student TU Delft)

M.J. Tenpierik (TU Delft - Building Physics)

M. Turrin (TU Delft - Design Informatics)

Research Group
Building Physics
Copyright
© 2020 Evangelia Despoina Giouri, M.J. Tenpierik, M. Turrin
DOI related publication
https://doi.org/10.1016/j.enbuild.2019.109666
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 Evangelia Despoina Giouri, M.J. Tenpierik, M. Turrin
Research Group
Building Physics
Volume number
209
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Currently 40% of EU's final energy consumption is attributed to buildings. Achieving the EU's climate targets would entail improved strategies in designing nearly Zero Energy Buildings. This research aimed to create an integrated decision-making strategy in designing ZEBs with the use of multi-objective optimization of building design and construction parameters for minimizing energy demand, while maximizing energy production and adaptive thermal comfort. Goal is to define which parameters have the highest impact and potential for further optimization and to offer an alternative to current stepped strategies such as the New Stepped Strategy. The proposed integrated approach is applied on a typical high-rise office building in Greece. Energy simulations with DesignBuilder are used as benchmark for the optimization run with EnergyPlus through Rhino and Grasshopper software via the plug-ins Honeybee and Ladybug, coupled with modeFRONTIER. For the first optimization round, the investigated parameters are: window-to-wall ratio, wall U-value, glazing construction U-value, glazing g-value, air-tightness of the facade, cooling set-point of the mechanical cooling system and PV facade surface area. For the second round, the parameters of window-to-wall ratio, shading area and PV surface area are adapted for four facade orientations. The optimizations resulted in a building with an annual final energy reduction of 33%.

Files

1_s2.0_S0378778818326343_main.... (pdf)
(pdf | 6.48 Mb)
- Embargo expired in 02-06-2020