Performance of a Phase Change Material Battery in a Transparent Building

Journal Article (2023)
Author(s)

Peter van den Engel (TU Delft - Building Services)

Michael Malin (CHAM, Bakery House)

Nikhilesh Kodur Venkatesh (Student TU Delft)

L. A. de Araujo Passos (TU Delft - Team Bart De Schutter)

Research Group
Building Services
Copyright
© 2023 P.J.W. van den Engel, Michael Malin, Nikhilesh Kodur Venkatesh, L.A. de Araujo Passos
DOI related publication
https://doi.org/10.32604/fdmp.2022.021962
More Info
expand_more
Publication Year
2023
Language
English
Copyright
© 2023 P.J.W. van den Engel, Michael Malin, Nikhilesh Kodur Venkatesh, L.A. de Araujo Passos
Research Group
Building Services
Issue number
3
Volume number
19
Pages (from-to)
783-805
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This research evaluates the performance of a Phase Change Material (PCM) battery integrated into the climate system of a new transparent meeting center. The main research questions are: a. “Can the performance of the battery be calculated?” and b. “Can the battery reduce the heating and cooling energy demand in a significant way?” The first question is answered in this document. In order to be able to answer the second question, especially the way the heat loading in winter should be improved, then more research is necessary. In addition to the thermal battery, which consists of Phase Change Material plates, the climate system has a cross-flow heat exchanger and a heat pump. The battery should play a central role in closing the thermal balance of the lightweight building, which can be loaded with hot return or cold outdoor air. The temperature of the battery plates is monitored by multi-sensors and simulated by the use of PHOENICS (Computational Fluid Dynamics) and MATLAB. This paper reports reasonable agreement between the numerical predictions and the measurements, with a maximum variance of 10%. The current coefficient of performance for heating and cooling is already high, more than 27. There is scope for increasing this much further by making use of the very low-pressure difference of the battery (below 25 Pascal), low pressure fans and the ventilation system as a whole.

Files

TSP_FDMP_21962.pdf
(pdf | 3.76 Mb)
License info not available