GPU-accelerated bi-objective treatment planning for prostate high-dose-rate brachytherapy

Journal Article (2019)
Author(s)

P.A. Bouter (Centrum Wiskunde & Informatica (CWI))

T. Alderliesten (Universiteit van Amsterdam)

Bradley R. Pieters (Universiteit van Amsterdam)

Arjan Bel (Universiteit van Amsterdam)

Yury Niatsetski (Elekta Brachytherapy)

P.A.N. Bosman (Centrum Wiskunde & Informatica (CWI), TU Delft - Algorithmics)

Research Group
Algorithmics
DOI related publication
https://doi.org/10.1002/mp.13681
More Info
expand_more
Publication Year
2019
Language
English
Research Group
Algorithmics
Issue number
9
Volume number
46
Pages (from-to)
3776-3787

Abstract

Purpose: The purpose of this study is to improve upon a recently introduced bi-objective treatment planning method for prostate high-dose-rate (HDR) brachytherapy (BT), both in terms of resulting plan quality and runtime requirements, to the extent that its execution time is clinically acceptable. Methods: Bi-objective treatment planning is done using a state-of-the-art multiobjective evolutionary algorithm, which produces a large number of potential treatment plans with different trade-offs between coverage of the target volumes and sparing organs at risk. A graphics processing unit (GPU) is used for large-scale parallelization of dose calculations and the calculation of the dose-volume (DV) indices of potential treatment plans. Moreover, the objectives of the previously used bi-objective optimization model are modified to produce better results. Results: We applied the GPU-accelerated bi-objective treatment planning method to a set of 18 patients, resulting in a set containing a few hundred potential treatment plans with different trade-offs for each of these patients. Due to accelerations introduced in this article, results previously achieved after 1 hour are now achieved within 30 seconds of optimization. We found plans satisfying the clinical protocol for 15 of 18 patients, whereas this was the case for only 4 of 18 clinical plans. Higher quality treatment plans are obtained when the accuracy of DV index calculation is increased using more dose calculation points, requiring still no more than 3 minutes of optimization for 100 000 points. Conclusions: Large sets of high-quality treatment plans that trade-off coverage and sparing are now achievable within 30 seconds, due to the GPU-acceleration of a previously introduced bi-objective treatment planning method for prostate HDR brachytherapy. Higher quality plans can be achieved when optimizing for 3 minutes, which we still consider to be clinically acceptable. This allows for more insightful treatment plan selection in a clinical setting.

No files available

Metadata only record. There are no files for this record.