Effect Of Interface Treatment On The Cracking Behaviour Of Hybrid SHCC (Strain Hardening Cementitious Composite) Concrete Beams

Conference Paper (2020)
Author(s)

Shozab Mustafa (TU Delft - Concrete Structures)

S. Singh (Student TU Delft)

M. Luković (TU Delft - Concrete Structures)

Research Group
Concrete Structures
Copyright
© 2020 S. Mustafa, S. Singh, M. Lukovic
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 S. Mustafa, S. Singh, M. Lukovic
Related content
Research Group
Concrete Structures
Pages (from-to)
456-462
ISBN (electronic)
9782940643042
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Strain Hardening Cementitious Composite (SHCC) is applied on the tension side of a flexural member in order to improve crack-width control of reinforced concrete and its effectiveness is investigated for varying treatment of the interface between SHCC and concrete. A four-point bending test configuration is used and the interface is varied locally within the constant bending moment region as smooth, partially debonded, completely debonded and profiled surface. The aim is to investigate the influence of interface on the cracking behaviour and the development of maximum crack-width in the hybrid SHCC beams with varying interface profile. Therefore, all the beams are designed to have a similar load carrying capacity by providing mechanical anchorage through the interface outside the constant bending moment region using stirrups. The cracking behaviour is analysed by measuring the maximum crack-width in SHCC layer using Digital Image Corelation (DIC), Linear Variable Differential Transformers (LVDTs) and visual inspection with a microscope. The effectiveness of the interface treatment is then judged by comparing the load at which the maximum crack-width in SHCC layer exceeds 0.3 mm, corresponding to the maximum allowable crack-width for most structural applications. It is observed that the relatively stronger interfaces (smooth and profiled) show better crack-width control when compared to partially debonded and completely debonded (weak) interfaces, probably because with weaker interface the hybrid action of the beam is reduced resulting in higher stresses and early crack localization in SHCC.

Files

P0667.pdf
(pdf | 0.823 Mb)
- Embargo expired in 24-05-2021
License info not available