Identification of the haemodynamic environment permissive for plaque erosion

Journal Article (2021)
Author(s)

Michael McElroy (The University of Manchester)

Yongcheol Kim (Yonsei University College of Medicine)

Giampaolo Niccoli (University of Parma)

Rocco Vergallo (Universita Cattolica del Sacro Cuore, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome)

Alexander Langford-Smith (Manchester Metropolitan University)

Filippo Crea (Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Universita Cattolica del Sacro Cuore)

Frank Gijsen (Erasmus MC, TU Delft - Applied Sciences)

Thomas Johnson

Amir Keshmiri (The University of Manchester)

undefined More Authors (External organisation)

Research Group
ChemE/Transport Phenomena
DOI related publication
https://doi.org/10.1038/s41598-021-86501-x Final published version
More Info
expand_more
Publication Year
2021
Language
English
Research Group
ChemE/Transport Phenomena
Issue number
1
Volume number
11
Article number
7253
Downloads counter
253
Collections
Institutional Repository
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Endothelial erosion of atherosclerotic plaques is the underlying cause of approximately 30% of acute coronary syndromes (ACS). As the vascular endothelium is profoundly affected by the haemodynamic environment to which it is exposed, we employed computational fluid dynamic (CFD) analysis of the luminal geometry from 17 patients with optical coherence tomography (OCT)-defined plaque erosion, to determine the flow environment permissive for plaque erosion. Our results demonstrate that 15 of the 17 cases analysed occurred on stenotic plaques with median 31% diameter stenosis (interquartile range 28-52%), where all but one of the adherent thrombi located proximal to, or within the region of maximum stenosis. Consequently, all flow metrics related to elevated flow were significantly increased (time averaged wall shear stress, maximum wall shear stress, time averaged wall shear stress gradient) with a reduction in relative residence time, compared to a non-diseased reference segment. We also identified two cases that did not exhibit an elevation of flow, but occurred in a region exposed to elevated oscillatory flow. Our study demonstrates that the majority of OCT-defined erosions occur where the endothelium is exposed to elevated flow, a haemodynamic environment known to evoke a distinctive phenotypic response in endothelial cells.