Effect of porosity variation strategy on the performance of functionally graded Ti-6Al-4V scaffolds for bone tissue engineering

Journal Article (2018)
Author(s)

Yu Xiang Zhang (Tsinghua University)

Gang Fang (Tsinghua University)

Lei Xing (Tsinghua University)

Wei Liu (Tsinghua University)

Jie Zhou (TU Delft - Biomaterials & Tissue Biomechanics)

Research Group
Biomaterials & Tissue Biomechanics
Copyright
© 2018 Xiang Yu Zhang, Gang Fang, Lei Lei Xing, Wei Liu, J. Zhou
DOI related publication
https://doi.org/10.1016/j.matdes.2018.07.064
More Info
expand_more
Publication Year
2018
Language
English
Copyright
© 2018 Xiang Yu Zhang, Gang Fang, Lei Lei Xing, Wei Liu, J. Zhou
Research Group
Biomaterials & Tissue Biomechanics
Volume number
157
Pages (from-to)
523-538
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Functionally graded scaffold (FGS) is designed to mimic the morphology, mechanical and biological properties of natural bone closely. Porosity variation strategy between different regions in FGS plays a crucial role in influencing its mechanical and biological performance. A combination of modeling tool and scripting language can effectively enhance the ability to optimize FGS design. This study was aimed at determining the effect of porosity variation strategy on the mechanical performance and permeability of the as-built and as-heat-treated FGSs. Ti-6Al-4V FGSs with sizes of 10 × 10 × 15 mm and diamond lattice structures were designed and fabricated by means of selective laser melting. A wide range of porosities in the FGSs (38–75%) were achieved by applying six different porosity variation strategies. The elastic modulus (3.7–5.7 GPa) and yield strength (27.1–84.7 MPa) of the as-built FGSs were found to vary between the corresponding mechanical properties of cancellous bone and cortical bone. Heat treatment reduced the strengths by 13–56%. Porosity variation strategy strongly affected the deformation behavior and failure mechanisms of the FGSs. The sigmoid function-controlled FGSs showed gradual failure behavior and sample Sigk0.5b8 showed superior overall performance. The results demonstrated that porosity variation strategy is a feasible means for tailor design of FGS.

Files

Effect_of_porosity_variation_s... (pdf)
(pdf | 3.43 Mb)
- Embargo expired in 08-08-2020