Extending the Open-Short de-embedding frequency via metal-l on-wafer calibration approaches

Conference Paper (2022)
Author(s)

C. Esposito (Technische Universität Dresden)

C. De Martino (TU Delft - Electronics, Vertigo Technologies)

Steffen Lehmann (GlobalFoundries)

Z. Zhao (GlobalFoundries)

S. Mothes (GlobalFoundries)

C. Kretzschmar (Technische Universität Dresden)

M. Schroter (Technische Universität Dresden)

M. Spirito (TU Delft - Electronics)

Research Group
Electronics
Copyright
© 2022 C. Esposito, C. De Martino, S. Lehmann, Z. Zhao, S. Mothes, C. Kretzschmar, M. Schroter, M. Spirito
DOI related publication
https://doi.org/10.1109/ARFTG54656.2022.9896529
More Info
expand_more
Publication Year
2022
Language
English
Copyright
© 2022 C. Esposito, C. De Martino, S. Lehmann, Z. Zhao, S. Mothes, C. Kretzschmar, M. Schroter, M. Spirito
Research Group
Electronics
Pages (from-to)
1-4
ISBN (print)
978-1-6654-6895-4
ISBN (electronic)
978-1-6654-6894-7
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

In this contribution, We analyze the bandwidth versus accuracy trade-offs of conventional two-step de-embedding approaches, often employed to extract the device model parameters. The accuracy limitation of incorporating the pad/line section of classical DUT test-fixtures into shunt-series complex and frequency-dependent elements is analyzed by means of linear circuit simulations and EM parametric analysis. The de-embedding accuracy is then evaluated by employing 3D surfaces to include both the frequency and the geometrical dependency. To validate the presented analysis, classical device monitoring parameters are extracted versus frequency for the same nMOS device embedded in two different fixtures. One topology only supports pad level calibration, thus including the fixture pad/line section in the de-embedding process. The second topology allows a direct on-Wafer calibration (reference plane set on metal-1 in close proximity to the DUT) thus minimizing the residual parasitics to be removed by the de-embedding step. Experimental data are then presented and compared to simulation test benches to highlight the improved consistency of the extracted model parameters of the metal-1 calibration approach up to 220GHz.