Extending the Open-Short de-embedding frequency via metal-l on-wafer calibration approaches

More Info
expand_more

Abstract

In this contribution, We analyze the bandwidth versus accuracy trade-offs of conventional two-step de-embedding approaches, often employed to extract the device model parameters. The accuracy limitation of incorporating the pad/line section of classical DUT test-fixtures into shunt-series complex and frequency-dependent elements is analyzed by means of linear circuit simulations and EM parametric analysis. The de-embedding accuracy is then evaluated by employing 3D surfaces to include both the frequency and the geometrical dependency. To validate the presented analysis, classical device monitoring parameters are extracted versus frequency for the same nMOS device embedded in two different fixtures. One topology only supports pad level calibration, thus including the fixture pad/line section in the de-embedding process. The second topology allows a direct on-Wafer calibration (reference plane set on metal-1 in close proximity to the DUT) thus minimizing the residual parasitics to be removed by the de-embedding step. Experimental data are then presented and compared to simulation test benches to highlight the improved consistency of the extracted model parameters of the metal-1 calibration approach up to 220GHz.

Files

Extending_the_Open_Short_de_em... (pdf)
(pdf | 2.43 Mb)
- Embargo expired in 01-07-2023