Hydrolysis capacity of different sized granules in a full-scale aerobic granular sludge (AGS) reactor

Journal Article (2022)
Author(s)

Sara Toja Ortega (TU Delft - Civil Engineering & Geosciences)

Lenno van den Berg (TU Delft - Civil Engineering & Geosciences)

Mario Pronk (TU Delft - Applied Sciences, Haskoning)

Merle K. de Kreuk (TU Delft - Civil Engineering & Geosciences)

Research Group
Sanitary Engineering
DOI related publication
https://doi.org/10.1016/j.wroa.2022.100151 Final published version
More Info
expand_more
Publication Year
2022
Language
English
Research Group
Sanitary Engineering
Volume number
16
Article number
100151
Downloads counter
331
Collections
Institutional Repository
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

In aerobic granular sludge (AGS) reactors, granules of different sizes coexist in a single reactor. Their differences in settling behaviour cause stratification in the settled granule bed. In combination with substrate concentration gradients over the reactor height during the anaerobic plug-flow feeding regime, this can result in functional differences between granule sizes. In this study, we compared the hydrolytic activity in granules of 4 size ranges (between 0.5 and 4.8 mm diameter) collected from a full-scale AGS installation. Protease and amylase activities were quantified through fluorescent activity assays. To visualise where the hydrolytic active zones were located within the granules, the hydrolysis sites were visualized microscopically after incubating intact and sliced granules with fluorescent casein and starch. The microbial community was studied using fluorescent in situ hybridization (FISH) and sequencing. The results of these assays indicated that hydrolytic capacity was present throughout the granules, but the hydrolysis of bulk substrates was restricted to the outer 100 µm, approximately. Many of the microorganisms studied by FISH, such as polyphosphate and glycogen accumulating organisms (PAO and GAO), were abundant in the vicinity of the hydrolytically active sites. The biomass-specific hydrolysis rate depended mainly on the available granule surface area, suggesting that different sized granules are not differentiated in terms of hydrolytic capacity. Thus, the substrate concentration gradients that are present during the anaerobic feeding in AGS reactors do not seem to affect hydrolytic activity at the granule surfaces. In this paper, we discuss the possible reasons for this and reflect about the implications for AGS technology.