Reduction of harmful noise pollution during hip replacement surgery

Master Thesis (2020)
Author(s)

C.L.H. Broekmeulen (TU Delft - Industrial Design Engineering)

Contributor(s)

Elif Ozcan – Mentor (TU Delft - Form and Experience)

Sonja Paus-Buzink – Graduation committee member (TU Delft - Human Factors)

H.H. Bodewes – Graduation committee member (TU Delft - Human Factors)

Yvonne Ywema – Coach (Zimmer Biomet Europe BV)

Faculty
Industrial Design Engineering
Copyright
© 2020 Kees Broekmeulen
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 Kees Broekmeulen
Graduation Date
30-06-2020
Awarding Institution
Delft University of Technology
Programme
['Integrated Product Design']
Faculty
Industrial Design Engineering
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

This graduation project is on behalf of TU Delft and Zimmer Biomet in collaboration with Orthopedic surgeons from Bergman Clinics, Orthopedic Clinic, in Naarden. The aim of this master thesis was to design a product which could reduce the pollution of harmful noise during hip replacement surgery. Noisy workplaces and especially within this procedure carry a large risk of noise-induced hearing loss, as sound levels of more than 120 decibels are generated by the usage of (powered) instruments. In the analysis phase observations in the operating theatre and interviews with experts are conducted to get insights and background information about the total hip arthroplasty procedures. It was found that noise levels experienced during surgery generated levels above the human pain threshold, ranging between 120-130 decibels and caused temporary and long-term noise induced hearing loss. Via a design vision and a list of requirements multiple concepts where generated. In the embodiment and evaluation phase, cadaver and saw bone testing showed that the new instrument design functioned and implant parts and/or tools could be implanted successfully. The outcome of this project is a new surgical instrument, which can press-fit (impact) and extract various implant components used during surgery. The instrument has multiple unique selling points compared to the currently used mallet as it reduces the noise level with more than 15 decibels and scores better on aspects of safety when looking into the risks at musculoskeletal disorders by improving surgical ergonomics. The instrument could be improved further when looking at the design and the current surgical workflow. Further research and clinical testing is necessary to see if this product is suitable for hip replacement surgery.

Files

Report_KeesBroekmeulen_4296265... (pdf)
(pdf | 80.6 Mb)
- Embargo expired in 22-06-2022
License info not available
Poster_KeesBroekmeulen_4296265... (pdf)
(pdf | 8.79 Mb)
- Embargo expired in 22-06-2022
License info not available
Productfoto1_KeesBroekmeulen_4... (jpg)
(jpg | 0.302 Mb)
- Embargo expired in 22-06-2022
License info not available
Productfoto2_KeesBroekmeulen_4... (jpg)
(jpg | 0.362 Mb)
- Embargo expired in 22-06-2022
License info not available