Dual Mode Electronic Quality Factor Control of 2D Phased Array Ultrasound Transducers for Imaging and Neuromodulation

Conference Paper (2025)
Author(s)

Anand A. Radhakrishnan (Student TU Delft)

M. Aqamolaei (TU Delft - Bio-Electronics)

Tiago L. Costa (TU Delft - Bio-Electronics)

Research Group
Bio-Electronics
DOI related publication
https://doi.org/10.1109/IUS62464.2025.11201673
More Info
expand_more
Publication Year
2025
Language
English
Research Group
Bio-Electronics
Bibliographical Note
Green Open Access added to TU Delft Institutional Repository as part of the Taverne amendment. More information about this copyright law amendment can be found at https://www.openaccess.nl. Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public. @en
ISBN (electronic)
9798331523329
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Ultrasound (US) technology has emerged as a powerful modality in both medical imaging and therapy, offering non-invasive, real-time, and high-resolution capabilities. Conventional dual-mode systems employ separate US transducers for imaging and therapy, each mechanically configured during fabrication for a fixed quality factor (Q-factor) through the presence of a backing layer or air-based backing layer, respectively. This approach increases system cost, physical footprint, power consumption, and integration complexity while preventing seamless real-time switching between modes. A novel electronically configurable Q-factor control circuit architecture for a single set of 2D phased-array piezoelectric transducers is proposed in this work. The proposed method employs an active damping compensation technique to electronically reduce the Q-factor during imaging mode while preserving the high-Q state for the therapeutic mode, eliminating the need for mechanical reconfiguration. System and circuit-level simulations in TSMC 180 nm BCD technology using a PZT-5A air-backed transducer BVD model demonstrate a reduction in the Q-factor from 78.3 to 8.08 with fewer than 1% variation across PVT corners. These results place the Q-factor achieved in the imaging mode within the optimal range for high-resolution ultrasound imaging, while maintaining high-Q performance for the therapeutic mode.