Thermal Crosstalk of X-Ray Transition-Edge Sensor Micro-Calorimeters under Frequency Domain Multiplexing Readout
Davide Vaccaro (SRON–Netherlands Institute for Space Research)
Hiroki Akamatsu (SRON–Netherlands Institute for Space Research)
Marcel Bruijn (SRON–Netherlands Institute for Space Research)
Luciano Gottardi (SRON–Netherlands Institute for Space Research)
Roland Den Hartog (SRON–Netherlands Institute for Space Research)
Jan Van Der Kuur (SRON–Netherlands Institute for Space Research)
Marcel Ridder (SRON–Netherlands Institute for Space Research)
Martin De Wit (SRON–Netherlands Institute for Space Research)
Jian Rong Gao (TU Delft - ImPhys/Optics, SRON–Netherlands Institute for Space Research)
undefined More Authors (External organisation)
More Info
expand_more
Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.
Abstract
We have measured and characterized the thermal crosstalk in two different arrays of transition-edge sensor (TES) X-ray microcalorimeters with frequency-domain multiplexing (FDM) readout. The TES arrays are fabricated at SRON and are a 8 × 8 and a 32 × 32 'kilo-pixel' uniform array. The amount of crosstalk is evaluated as the ratio between the averaged crosstalk signal and the X-ray pulse amplitudes. The crosstalk ratios (CRs) for our detectors are compliant with the requirements for future X-ray space missions, such as Athena X-IFU (CR < 10^{-3 for first-neighbor pixels): We measured a nearest neighbor thermal CR at a level of 10^{-4, with a highest CR of 4× 10^{-4 for the kilo-pixel array (worst case, center of array) and 1× 10^{-4 for the 8 × 8 array, with a margin of improvement achievable by optimizing the Cu metallization and the width of the Si supporting structures (muntins) in the backside of the TES array chip. Based on the measured CRs, we have estimated the impact on the spectral resolution by means of noise equivalent power considerations and a Monte Carlo simulation, finding an average degradation in quadrature of less than 40 meV, compliant with the <0.2 eV requirement for Athena X-IFU.