Geometrically induced wall shear stress variability in CFD-MRI coupled simulations of blood flow in the thoracic aortas

Journal Article (2021)
Authors

R. Perinajová (TU Delft - ChemE/Transport Phenomena)

Joe F. Juffermans (Leiden University Medical Center)

Jos Westenberg (Leiden University Medical Center)

Roel L.F. van der Palen (Leiden University Medical Center)

Pieter J. van den Boogaard (Leiden University Medical Center)

Hildo J. Lamb (Leiden University Medical Center)

S. KenjereS (TU Delft - ChemE/Transport Phenomena)

Research Group
ChemE/Transport Phenomena
Copyright
© 2021 R. Perinajová, Joe F. Juffermans, Jos J.M. Westenberg, Roel L.F. van der Palen, Pieter J. van den Boogaard, Hildo J. Lamb, S. Kenjeres
More Info
expand_more
Publication Year
2021
Language
English
Copyright
© 2021 R. Perinajová, Joe F. Juffermans, Jos J.M. Westenberg, Roel L.F. van der Palen, Pieter J. van den Boogaard, Hildo J. Lamb, S. Kenjeres
Research Group
ChemE/Transport Phenomena
Volume number
133
DOI:
https://doi.org/10.1016/j.compbiomed.2021.104385
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

Aortic aneurysm is associated with aberrant blood flow and wall shear stress (WSS). This can be studied by coupling magnetic resonance imaging (MRI) with computational fluid dynamics (CFD). For patient-specific simulations, extra attention should be given to the variation in segmentation of the MRI data-set and its effect on WSS. We performed CFD simulations of blood flow in the aorta for ten different volunteers and provided corresponding WSS distributions. The aorta of each volunteer was segmented four times. The same inlet and outlet boundary conditions were applied for all segmentation variations of each volunteer. Steady-state CFD simulations were performed with inlet flow based on phase-contrast MRI during peak systole. We show that the commonly used comparison of mean and maximal values of WSS, based on CFD in the different segments of the thoracic aorta, yields good to excellent correlation (0.78–0.95) for rescan and moderate to excellent correlation (0.64–1.00) for intra- and interobserver reproducibility. However, the effect of geometrical variations is higher for the voxel-to-voxel comparison of WSS. With this analysis method, the correlation for different segments of the whole aorta is poor to moderate (0.43–0.66) for rescan and poor to good (0.48–0.73) for intra- and interobserver reproducibility. Therefore, we advise being critical about the CFD results based on the MRI segmentations to avoid possible misinterpretation. While the global values of WSS are similar for different modalities, the variation of results is high when considering the local distributions.