K-Space Trajectory Design for Reduced MRI Scan Time

Conference Paper (2020)
Author(s)

Shubham Sharma (Indian Institute of Science)

K.V.S. Hari (Indian Institute of Science)

Geert Leus (TU Delft - Signal Processing Systems)

Research Group
Signal Processing Systems
Copyright
© 2020 S. Sharma, K.V.S. Hari, G.J.T. Leus
DOI related publication
https://doi.org/10.1109/ICASSP40776.2020.9054306
More Info
expand_more
Publication Year
2020
Language
English
Copyright
© 2020 S. Sharma, K.V.S. Hari, G.J.T. Leus
Research Group
Signal Processing Systems
Bibliographical Note
Green Open Access added to TU Delft Institutional Repository ‘You share, we take care!’ – Taverne project https://www.openaccess.nl/en/you-share-we-take-care Otherwise as indicated in the copyright section: the publisher is the copyright holder of this work and the author uses the Dutch legislation to make this work public.@en
Pages (from-to)
1120-1124
ISBN (print)
978-1-5090-6632-2
ISBN (electronic)
978-1-5090-6631-5
Reuse Rights

Other than for strictly personal use, it is not permitted to download, forward or distribute the text or part of it, without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license such as Creative Commons.

Abstract

The development of compressed sensing (CS) techniques for magnetic resonance imaging (MRI) is enabling a speedup of MRI scanning. To increase the incoherence in the sampling, a random selection of points on the k-space is deployed and a continuous trajectory is obtained by solving a traveling salesman problem (TSP) through these points. A feasible trajectory satisfying the gradient constraints is then obtained by parameterizing it using state-of-the-art methods. In this paper, a constrained convex optimization based method to obtain feasible trajectories is proposed. The method is motivated by the fact that the readout time is proportional to the number of sample points and includes the lengths of the segments of the trajectory in the cost function to obtain variable length trajectories. The proposed method provides a reduction in readout time by more than 50% for random-like trajectories with an improvement of about 1.5 dB in peak signal-to-noise ratio (PSNR) and 0.0762 in structural similarity (SSIM) index on average for a realistic brain phantom MRI image adopting single-shot trajectories.

Files

K_Space_Trajectory_Design_for_... (pdf)
(pdf | 0.863 Mb)
- Embargo expired in 14-11-2020
License info not available