Design and control of an energy storage system for voltage flicker caused by clouds passing over photovoltaic systems
More Info
expand_more
Abstract
As more and more solar panels are installed on households, a problem arises when the power from the solar panels fluctuating throughout the day due to clouds passing over the solar panels. This in turn causes voltage flickers in the household, which can be visible/irritable to the human eye and damage appliances in the household. These voltage flickers can exceed limits set by the IEC standard 61000-3-7 or the visible flicker threshold on the Low Voltage (LV) network set by Qualtech [1]. This problem can be solved by making use of an Energy Storage System (ESS) which delivers active power in order to reduce and avoid the voltage fluctuations above the visible flicker threshold. In this report, a novel control algorithm is designed and implemented in two different ways to control the active power dispatch of the ESS. The main goal for the control algorithm is to reduce or avoid any visible voltage flickers from occurring and minimizing energy usage asmuch as possible in order to open the possibility for a Supercapacitor Energy Storage System (SESS) application in the future. For this, a power to energy ratio of higher than 70 is needed to achieve this. The primary control algorithm makes use of a moving average with a weight distribution that is optimised for smoothness and accuracy. Furthermore, extra layers of control was added to the control algorithm tominimize energy usage. The first implementation of the control algorithm, called power control, makes use of the Photovoltaic (PV) system output power to dispatch the appropriate amount of power from the ESS. The second implementation, called voltage control, makes use of the measured voltage at Point of Common Coupling (PCC) to dispatch the ESS power. Simulation results using pre-existing PV system data showed that the power control implementation was not able to fully eradicate all of the measured visible and annoying voltage flickers. The voltage control implementation was able to do so within the window of operation. Furthermore, simulation results showed that the energy usage from the control algorithm with a power control implementation uses 87% percent less energy than a control algorithm using conventional moving average. The energy usage from the control algorithm with a voltage control implementation uses 95% less energy than the conventional moving average control algorithm. Furthermore, the power to energy ratio of the control algorithm with a power control implementation was around 98.9 and with a voltage control implementation the power to energy ratio was around 190.2. This shows a clear implementation of a SESS in the future. Two different experimental setups were built and commissioned. The first setup having the Battery Energy Storage System (BESS) connected via an inverter on the same Alternating Current (AC) bus with the PV system. The second setup has the BESS connected on the same Direct Current (DC) bus with the PV system which is then connected to an inverter. Experiment results showed that the DC connected ESS experiment setup operating in power control mode had the best performance in terms of avoiding any visible voltage flickers from occurring. While the AC experimental setup and mode of operation (voltage and power control mode) did not operate properly due to the slow inverter response time. In terms of energy usage, both experimental setups had very low ESS energy usage. Although the results showed that power to energy ratio from both experimental setups using both power and voltage control did not exceed the set goal of 70 due to the limitations of both experimental setups. Finally, a conclusion based on the results is given with future work and as well as recommendations for the continuation on this research topic.
Files
File under embargo until 09-11-2025
File under embargo until 09-11-2025