Cahalane, Rachel M.E. (author), Cruts, Janneke M.H. (author), van Beusekom, Heleen M.M. (author), de Maat, Moniek P.M. (author), Dijkshoorn, Marcel (author), van der Lugt, Aad (author), Gijsen, F.J.H. (author)
Thrombus computed tomography (CT) imaging characteristics may correspond with thrombus mechanical properties and thus predict thrombectomy success. The impact of red blood cell (RBC) content on these properties (imaging and mechanics) has been widely studied. However, the additional effect of platelets has not been considered. The objective...
journal article 2024
document
Tourais, Joao (author), Ploem, T.W. (author), Zadelhoff, Tijmen A.van (author), Steeg-Henzen, Christal van de (author), Oei, Edwin H.G. (author), Weingärtner, S.D. (author)
Objective: Quantitative Magnetic Resonance Imaging (MRI) holds great promise for the early detection of cartilage deterioration. Here, a Magnetic Resonance Fingerprinting (MRF) framework is proposed for comprehensive and rapid quantification of T <sub>1</sub>, T <sub>2</sub> <sup>∗</sup>, and T <sub>RAFF2</sub> with whole-knee coverage....
journal article 2023
document
van der Meulen, P.Q. (author), Coutino, Mario (author), Bosch, Johannes G. (author), Kruizinga, P. (author), Leus, G.J.T. (author)
We consider the scenario of finding the transfer function of an aberrating layer in front of a receiving ultrasound (US) array, assuming a separate non-aberrated transmit source. We propose a method for blindly estimating this transfer function without exact knowledge of the ultrasound sources or acoustic contrast image, and without directly...
journal article 2023
document
Zangabad, Reza Pakdaman (author), Li, H. (author), Kouijzer, Joop J.P. (author), Langeveld, Simone A.G. (author), Beekers, Ines (author), Verweij, M.A. (author), de Jong, N. (author), Kooiman, Klazina (author)
Understanding and controlling the ultrasound contrast agent (UCA)'s response to an applied ultrasound pressure field are crucial when investigating ultrasound imaging sequences and therapeutic applications. The magnitude and frequency of the applied ultrasonic pressure waves affect the oscillatory response of the UCA. Therefore, it is...
journal article 2023
document
Hoogelander, M. (author), van Berkel, S.L. (author), Malotaux, E.S. (author), Alonso Del Pino, M. (author), Cavallo, D. (author), Spirito, M. (author), Llombart, Nuria (author)
This article presents the development of a focal plane array (FPA) for terahertz imaging applications with a near diffraction-limited resolution achieved through a very tight sampling of the focal plane. The antenna array is integrated with direct detectors in a 22-nm CMOS technology and operates from 200 to 600 GHz. The tight sampling of the...
journal article 2023
document
Hopf, Y.M. (author), Ossenkoppele, Boudewine W. (author), Soozande, Mehdi (author), Noothout, E.C. (author), Chang, Z.Y. (author), Chen, Chao (author), Vos, H.J. (author), Bosch, Johan G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The...
journal article 2022
document
Guo, P. (author), Chang, Z.Y. (author), Noothout, E.C. (author), Vos, H.J. (author), Bosch, Johan G. (author), de Jong, N. (author), Verweij, M.D. (author), Pertijs, M.A.P. (author)
This article presents a compact analog front-end (AFE) circuit for ultrasound receivers with linear-in-dB continuous gain control for time-gain compensation (TGC). The AFE consists of two variable-gain stages, both of which employ a novel complementary current-steering network (CCSN) as the interpolator to realize continuously variable gain....
journal article 2022
document
Mozaffarzadeh, M. (author), Verschuur, D.J. (author), Verweij, M.D. (author), Daeichin, V. (author), de Jong, N. (author), Renaud, G.G.J. (author)
Transcranial ultrasound imaging (TUI) is a diagnostic modality with numerous applications, but unfortunately, it is hindered by phase aberration caused by the skull. In this article, we propose to reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. First, the compressional sound...
journal article 2022
document
Wahyulaksana, G. (author), Wei, Luxi (author), Schoormans, Jasper (author), Voorneveld, J.D. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Vos, H.J. (author)
Suppressing tissue clutter is an essential step in blood flow estimation and visualization, even when using ultrasound contrast agents. Blind source separation (BSS)-based clutter filter for high-framerate ultrasound imaging has been reported to perform better in tissue clutter suppression than the conventional frequency-based wall filter and...
journal article 2022
document
Zhao, Yubin (author), Yarovoy, Alexander (author), Fioranelli, F. (author)
The need for technologies for Human Activity Recognition (HAR) in home environments is becoming more and more urgent because of the aging population worldwide. Radar-based HAR is typically using micro-Doppler signatures as one of the main data representations, in conjunction with classification algorithms often inspired from deep learning...
journal article 2022
document
Barstow, M. A. (author), Aigrain, S. (author), Barstow, J. K. (author), Barthelemy, M. (author), Evans, C. (author), Ferrari, M. (author), Garcia, M. (author), Rossi, L. (author), Stam, D.M. (author)
One of the most exciting scientific challenges is to detect Earth-like planets in the habitable zones of other stars in the galaxy and search for evidence of life. During the past 20 years the detection of exoplanets, orbiting stars beyond our own, has moved from science fiction to science fact. From the first handful of gas giants, found...
journal article 2021
document
Wei, Luxi (author), Wahyulaksana, G. (author), Meijlink, Bram (author), Ramalli, Alessandro (author), Noothout, E.C. (author), Verweij, M.D. (author), van der Steen, A.F.W. (author), de Jong, N. (author), Vos, H.J. (author)
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter...
journal article 2021
document
Davydenko, M.V. (author), Verschuur, D.J. (author)
Waveform inversion based on least-squares reverse time migration (LSRTM) usually involves Born modeling, which models the primary-only data. As a result the inversion process handles only primaries and corresponding multiple elimination pre-processing of the input data is required prior to imaging and inversion. Otherwise, multiples left in...
journal article 2021
document
Revelo Obando, B.A. (author), Blacquière, G. (author)
Seismic data are traditionally acquired based on spatial sampling requirements, noise properties and budgetary constraints. However, designing a survey without taking into account the complexity of the subsurface may result in an image without the expected quality. Also, the subsequent preprocessing and processing steps may exploit or misuse...
journal article 2021
document
Chamarczuk, Michał (author), Malinowski, Michał (author), Draganov, D.S. (author)
Despite the unrivalled spatial resolution and depth penetration of active-source seismic methods used for mineral exploration in hardrock environment, economic and environmental restrictions (e.g., source permitting) may preclude its full-scale application. In such a case, 2D passive reflection seismics can be considered a cost-effective way...
journal article 2021
document
Wei, Wei (author), Blacquière, G. (author)
Focal beam analysis has built a bridge between the acquisition parameters on the surface and the image quality of underground targets. However, as a practical matter, it is still difficult to answer how to choose a proper acquisition geometry according to the complexity of medium, especially considering the contradictory effects of multiple...
journal article 2021
document
Sun, Yimin (author), Kim, Young Seo (author), Qu, S. (author), Verschuur, D.J. (author)
Joint migration inversion is a recently proposed technology, accommodating velocity model building and seismic migration in one integrated process. Different from the widely accepted full waveform inversion technology, it uses imaging parameters, i.e. velocities and reflectivities of the subsurface, to parameterize its solution space. The...
journal article 2020
document
Gielis, W. P. (author), Weinans, Harrie (author), Welsing, P. M.J. (author), van Spil, W. E. (author), Agricola, R. (author), Cootes, T. F. (author), de Jong, P. A. (author), Lindner, C. (author)
Objective: To design an automated workflow for hip radiographs focused on joint shape and tests its prognostic value for future hip osteoarthritis. Design: We used baseline and 8-year follow-up data from 1,002 participants of the CHECK-study. The primary outcome was definite radiographic hip osteoarthritis (rHOA) (Kellgren–Lawrence grade ≥2...
journal article 2020
document
Vinke, Elisabeth J. (author), Huizinga, W. (author), Bergtholdt, Martin (author), Adams, Hieab H. (author), Steketee, Rebecca M.E. (author), Papma, Janne M. (author), De Jong, Frank Jan (author), Niessen, W.J. (author), Ikram, M. Arfan (author)
Brain imaging data are increasingly made publicly accessible, and volumetric imaging measures derived from population-based cohorts may serve as normative data for individual patient diagnostic assessment. Yet, these normative cohorts are usually not a perfect reflection of a patient's base population, nor are imaging parameters such as field...
journal article 2019
document
Tan, M. (author), Chen, C. (author), Chen, Z. (author), Janjic, Jovana (author), Daeichin, V. (author), Chang, Z.Y. (author), Noothout, E.C. (author), van Soest, G. (author), Verweij, M.D. (author), de Jong, N. (author), Pertijs, M.A.P. (author)
This paper presents an area- and power-efficient application-specified integrated circuit (ASIC) for 3-D forward-looking intravascular ultrasound imaging. The ASIC is intended to be mounted at the tip of a catheter, and has a circular active area with a diameter of 1.5 mm on the top of which a 2-D array of piezoelectric transducer elements is...
journal article 2018