document
Vlieger, H. (author)
This report presents results of residual strength calculations, carried out on cracked panel configurations of various designs and provided with bonded stiffeners. The calculations were carried out using the computer program BOND. The results of these calculations are compared with results of residual strength tests, performed on panels of...
report 1983
document
Bartelds, G. (author)
report 1978
document
't Hart, W.G.J. (author)
Residual strength tests have heen performed, on 300 mm wide centrecracked panels of various thicknesses, at room temperature and at -50 C. During the tests, stable crack growth was filmed and recorded with the electric potential method. Fracture toughness was determined using the method of Feddersen.
report 1976
document
Vlieger, H. (author)
Residual strength tests were carried out on center-cracked panels with a 2024-T3 or 7075-T6 skin and provided with eccentric stiffeners of practical design. The stiffeners were riveted to the skin. The material of the stiffeners was 7075-T6. In some cases the stiffeners were combined with Ti-alloy crack stoppers. On the basis of the test results...